Case study on thermal design and analysis of a sub-Kelvin cryogenic system for the CSNS-II ultracold neutron source

To support the Phase II ultracold neutron source at China Spallation Neutron Source, a sub-Kelvin cryogenic system capable of maintaining a 70 mm × 70 mm × 1000 mm superfluid helium converter below 0.7 K was designed and thermally analyzed. The system integrates a 1.4 K 4 He loop, a 0.5 K 3 He loop, and an ultrapure 4 He loop. Thermal loads from structural conduction, radiation, residual gas conduction, and process cooling were evaluated. The optimal 3 He inlet pressure was determined as 95 000 Pa to achieve balanced thermal load distribution. A spiral heat exchanger with a required tube length of 191 mm was designed for 2.6 K precooling. The minimum required 3 He– 4 He interfacial heat transfer area was calculated as 456 cm 2 . A porous alumina superleak achieved a 3 He/ 4 He isotopic ratio of 10 −10 . Four GM cryocoolers satisfy the total cooling demand of 89.49 W at 45 K and 1.958 W at 3.05 K.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-11-21
DOI
https://doi.org/10.1016/j.csite.2026.108741
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Case study on thermal design and analysis of a sub-Kelvin cryogenic system for the CSNS-II ultracold neutron source

Meiying Ding, Yu Yang, Tiancheng Yi, Haodong Wang et al.
Case Studies in Thermal Engineering
Spacecraft and Cryogenic Technologies
article

Case study on thermal design and analysis of a sub-Kelvin cryogenic system for the CSNS-II ultracold neutron source

Meiying Ding, Yu Yang, Tiancheng Yi, Haodong Wang, Kun He, Yijie Cai, Jianzhen Li, Yang Meng, Songlin Wang, Dongdong Wang, Yu Zhang, Dongdong Zhou, Tianjiao Liang, Qidong He, Xuefen Han
article en

Abstract

To support the Phase II ultracold neutron source at China Spallation Neutron Source, a sub-Kelvin cryogenic system capable of maintaining a 70 mm × 70 mm × 1000 mm superfluid helium converter below 0.7 K was designed and thermally analyzed. The system integrates a 1.4 K 4 He loop, a 0.5 K 3 He loop, and an ultrapure 4 He loop. Thermal loads from structural conduction, radiation, residual gas conduction, and process cooling were evaluated. The optimal 3 He inlet pressure was determined as 95 000 Pa to achieve balanced thermal load distribution. A spiral heat exchanger with a required tube length of 191 mm was designed for 2.6 K precooling. The minimum required 3 He– 4 He interfacial heat transfer area was calculated as 456 cm 2 . A porous alumina superleak achieved a 3 He/ 4 He isotopic ratio of 10 −10 . Four GM cryocoolers satisfy the total cooling demand of 89.49 W at 45 K and 1.958 W at 3.05 K.

Case Studies in Thermal EngineeringVol. 88
Chinese Academy of Sciences (CN), China Spallation Neutron Source (CN), Institute of High Energy Physics (CN), Xi'an Jiaotong University (CN)
Spacecraft and Cryogenic Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Case study on thermal design and analysis of a sub-Kelvin cryogenic system for the CSNS-II ultracold neutron source — Meiying Ding, Yu Yang, et al. · Case Studies in Thermal Engineering (2026) | TGRS Research Map | TGRS