Marginal Bone Loss Around Platform-Switching and Platform-Matching Implants in Anterior and Posterior Sites: A Retrospective Study
Introduction: Preservation of marginal bone is essential for the long-term stability and success of dental implants. The implant-abutment interface configuration may influence peri-implant bone remodeling; however, the magnitude of this effect across different anatomical sites has not been fully clarified. This study compared 12-month marginal bone loss (MBL) between platform-switching and platform-matching implants and evaluated whether the association differed according to implant location (anterior versus posterior). Materials and methods: This retrospective observational study analyzed 104 dental implants (52 platform-switching and 52 platform-matching). MBL was measured on digital intraoral periapical radiographs obtained 12 months after delivery of the definitive restoration. Mesial, distal, and mean implant-level bone loss were compared between the two configurations. Group differences were assessed using Welch’s independent-samples t-test. Two-way analysis of variance (ANOVA) was used to examine the effects of implant configuration, site location (anterior or posterior), and their interaction. Tukey-Kramer post hoc comparisons were performed when appropriate. Statistical significance was set at p < 0.05. Results: At 12 months, mean implant-level MBL was significantly lower with platform-switching implants (0.61 ± 0.19 mm) than with platform-matching implants (0.84 ± 0.15 mm), yielding a mean difference of −0.23 mm (95% CI: −0.29 to −0.16; p < 0.001; Cohen’s d = −1.33). Mesial and distal bone loss were also significantly lower in the platform-switching group (both p < 0.001). The mean difference was −0.27 mm in anterior sites (95% CI: −0.36 to −0.17; p < 0.001) and −0.20 mm in posterior sites (95% CI: −0.28 to −0.11; p < 0.001). Two-way ANOVA showed a significant main effect of implant configuration (p < 0.001). Neither the main effect of site location (p = 0.241) nor the configuration-by-location interaction (p = 0.286) reached statistical significance. Conclusion: In this retrospective sample, platform-switching implants were associated with lower 12-month MBL than platform-matching implants. The association was observed in both anterior and posterior sites, with no evidence of a statistically significant interaction between implant configuration and site location. These findings do not establish a causal relationship. Prospective studies with longer follow-up are needed to determine the clinical relevance and long-term durability of the observed association.
Authors
- Sameer Chauhan (ORCID: https://orcid.org/0000-0002-2467-622X)
- Aditi Kanitkar (ORCID: https://orcid.org/0000-0002-6661-0931)
- Nishtha Agrawal
- Rashi Negi (ORCID: https://orcid.org/0009-0006-4918-3647)
- Anip K Roy
- Gangadhar B
Publication Details
- Journal
- Cureus
- Published
- 2026-11-21
- DOI
- https://doi.org/10.7759/cureus.120048
- Primary Topic
- Dental Implant Techniques and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00