Numerical–experimental assessment of embedded heat exchanger configurations for geothermal anti-icing pavements: thermal performance and surface temperature distribution

Geothermal anti-icing pavements represent a promising solution for improving road safety under freezing conditions; however, the thermal performance of different embedded heat exchanger layouts remains insufficiently characterized. This study presents a numerical–experimental framework to assess three complete collector configurations (helical, U-bend serpentine, and longitudinal) for geothermal pavement heating applications. The analysis combines a fluid energy-balance model with topology-specific spatial heat-transfer formulations and harmonized operating conditions. Under the conditions and numerical formulations considered, the helical and U-bend configurations provided the strongest surface-heating responses, whereas the evaluated longitudinal configuration showed lower spatial coverage. Numerical predictions agreed with the experimental observations, with mean absolute errors below 0.7 °C, and infrared thermography reproduced the characteristic spatial heating patterns. Sensitivity analysis showed that inlet fluid temperature, installation depth, and the effective overall linear heat-transfer coefficient UA' exerted the strongest influence on the evaluated thermal-performance metrics. At road scale, a hybrid helical–serpentine arrangement reduced the equivalent scaled heat-release capacity by approximately 37% relative to a uniform helical extrapolation; this capacity reduction does not by itself demonstrate a proportional reduction in operational energy consumption. The results support preliminary configuration selection while explicitly recognizing that the S1 comparison does not isolate geometry independently of the topology-specific numerical formulation.

Authors

Institutions

Publication Details

Journal
Geothermics
Published
2026-11-21
DOI
https://doi.org/10.1016/j.geothermics.2026.103891
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Numerical–experimental assessment of embedded heat exchanger configurations for geothermal anti-icing pavements: thermal performance and surface temperature distribution

Cristina Sáez Blázquez, Miguel Ángel Maté‐González, Sergio Alejandro Camargo Vargas, Daniel Herranz Herranz et al.
Geothermics
Geothermal Energy Systems and Applications
article

Numerical–experimental assessment of embedded heat exchanger configurations for geothermal anti-icing pavements: thermal performance and surface temperature distribution

Cristina Sáez Blázquez, Miguel Ángel Maté‐González, Sergio Alejandro Camargo Vargas, Daniel Herranz Herranz, Miguel Álvarez Rubio
article en

Abstract

Geothermal anti-icing pavements represent a promising solution for improving road safety under freezing conditions; however, the thermal performance of different embedded heat exchanger layouts remains insufficiently characterized. This study presents a numerical–experimental framework to assess three complete collector configurations (helical, U-bend serpentine, and longitudinal) for geothermal pavement heating applications. The analysis combines a fluid energy-balance model with topology-specific spatial heat-transfer formulations and harmonized operating conditions. Under the conditions and numerical formulations considered, the helical and U-bend configurations provided the strongest surface-heating responses, whereas the evaluated longitudinal configuration showed lower spatial coverage. Numerical predictions agreed with the experimental observations, with mean absolute errors below 0.7 °C, and infrared thermography reproduced the characteristic spatial heating patterns. Sensitivity analysis showed that inlet fluid temperature, installation depth, and the effective overall linear heat-transfer coefficient UA' exerted the strongest influence on the evaluated thermal-performance metrics. At road scale, a hybrid helical–serpentine arrangement reduced the equivalent scaled heat-release capacity by approximately 37% relative to a uniform helical extrapolation; this capacity reduction does not by itself demonstrate a proportional reduction in operational energy consumption. The results support preliminary configuration selection while explicitly recognizing that the S1 comparison does not isolate geometry independently of the topology-specific numerical formulation.

GeothermicsVol. 143
Universidad de Salamanca (ES)
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon