Secondary Organic Aerosol Formation from Cleaning Product Use in a Residential Kitchen

Secondary organic aerosol (SOA) can form indoors when volatile organic compounds (VOCs), commonly emitted from the use of scented cleaning products and other chemical products, undergo oxidation and condense onto aerosols. Indoor oxidants can come from a variety of sources, including the use of chlorine bleach for surface cleaning and disinfection, operation of germicidal ultraviolet (GUV) lamps for air disinfection, and penetration of ozone (O 3 ) from the outdoor environment. During the Consumer products, Lights, and Environmental Air cleaning in Normal conditions (CLEAN) Home Study, we measured SOA formation in a real home after performing surface cleaning with a scented all-purpose cleaning liquid and subsequently introducing different indoor oxidant scenarios. Six oxidant scenarios were tested, including (1) bleach surface cleaning, (2) O 3 injection, (3) 222 nm GUV (GUV222) lamp operation, (4) 254 nm GUV (GUV254) lamp operation, and bleach surface cleaning with subsequent (5) GUV222 or (6) GUV254 lamp operation. Spraying the cleaning liquid emitted high concentrations of large primary particles and monoterpenes indoors. SOA formation occurred after cleaning liquid application and subsequent oxidant introduction for all oxidant scenarios except for bleach cleaning without subsequent GUV illumination. The oxidant scenario that led to the most SOA formation was bleach cleaning with GUV254 lamp operation. We used a chemical kinetic model to simulate monoterpene and aerosol concentrations indoors during cleaning liquid experiments with three oxidant scenarios: O 3 injection, GUV222 lamp operation, and GUV254 lamp operation. We compared model results to our measurements for these select experiments. Results from this study demonstrate that indoor cleaning activities can lead to significant SOA formation in real indoor environments.

Authors

Institutions

Publication Details

Journal
ChemRxiv
Published
2026-11-20
DOI
https://doi.org/10.26434/chemrxiv.15012529/v1
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Secondary Organic Aerosol Formation from Cleaning Product Use in a Residential Kitchen

Kelvin H. Bates, Marina E. Vance, Qing Ye, Sofie K. Schwink et al.
ChemRxiv
Indoor Air Quality and Microbial Exposure
preprint

Secondary Organic Aerosol Formation from Cleaning Product Use in a Residential Kitchen

Kelvin H. Bates, Marina E. Vance, Qing Ye, Sofie K. Schwink, Rebecca Mesburis, Joost de Gouw, Jose L. Jimenez, Matthew C. Shulman, Rileigh Robertson, Darrah P. Boyle, Ethan P. Richter
preprint en

Abstract

Secondary organic aerosol (SOA) can form indoors when volatile organic compounds (VOCs), commonly emitted from the use of scented cleaning products and other chemical products, undergo oxidation and condense onto aerosols. Indoor oxidants can come from a variety of sources, including the use of chlorine bleach for surface cleaning and disinfection, operation of germicidal ultraviolet (GUV) lamps for air disinfection, and penetration of ozone (O 3 ) from the outdoor environment. During the Consumer products, Lights, and Environmental Air cleaning in Normal conditions (CLEAN) Home Study, we measured SOA formation in a real home after performing surface cleaning with a scented all-purpose cleaning liquid and subsequently introducing different indoor oxidant scenarios. Six oxidant scenarios were tested, including (1) bleach surface cleaning, (2) O 3 injection, (3) 222 nm GUV (GUV222) lamp operation, (4) 254 nm GUV (GUV254) lamp operation, and bleach surface cleaning with subsequent (5) GUV222 or (6) GUV254 lamp operation. Spraying the cleaning liquid emitted high concentrations of large primary particles and monoterpenes indoors. SOA formation occurred after cleaning liquid application and subsequent oxidant introduction for all oxidant scenarios except for bleach cleaning without subsequent GUV illumination. The oxidant scenario that led to the most SOA formation was bleach cleaning with GUV254 lamp operation. We used a chemical kinetic model to simulate monoterpene and aerosol concentrations indoors during cleaning liquid experiments with three oxidant scenarios: O 3 injection, GUV222 lamp operation, and GUV254 lamp operation. We compared model results to our measurements for these select experiments. Results from this study demonstrate that indoor cleaning activities can lead to significant SOA formation in real indoor environments.

ChemRxiv
NSF National Center for Atmospheric Research (US), Cooperative Institute for Research in Environmental Sciences (US), University of Colorado Boulder (US), NSF NCAR Atmospheric Chemistry Observations & Modeling (US)
National Science Foundation, Natural Sciences and Engineering Research Council of Canada
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon