Smoke spread and visibility loss in an aircraft cabin: implications for evacuation and firefighting
Smoke obscuration affects visual orientation during aircraft-cabin evacuation and firefighting access. We analysed three Fire Dynamics Simulator calculations with front, middle and rear prescribed sources reaching 100 kW in a generic single-aisle cabin under common ventilation conditions. Temperature and soot-density fields were combined with records at seven aisle stations and three heights to examine smoke spread and reflecting-target visibility. Reduced visibility extended beyond the most strongly heated regions and varied with longitudinal position and height. At 1.7 m, seven, seven and four stations in the front, middle and rear cases recorded interval-mean visibility below a descriptive 10 m comparison level; at 2.1 m, all seven did so in each case. A lower-height station near the middle source reached 1.74 m. An independent historical Boeing 707 cargo comparison showed that replacing experimental endpoint samples with interval means increased optical root mean square error by 15.42% at fixed comparison labels. The results identify spatial optical conditions for assessing evacuation wayfinding and firefighter orientation alongside thermal and gas conditions.
Authors
- Changyuan He (ORCID: https://orcid.org/0009-0009-5716-6494)
- Yanbo Yin (ORCID: https://orcid.org/0009-0008-0973-8198)
- Gang Wang
- Pei Wang
- Mengjie Liang
Institutions
- Beijing Normal University (CN)
- Civil Aviation Management Institute of China (CN)
- China Fire and Rescue Institute (CN)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-20
- DOI
- https://doi.org/10.21203/rs.3.rs-11588619/v1
- Primary Topic
- Fire dynamics and safety research
- Type
- preprint