Physiological digital twins require cross-system observation contracts

Whole-body models explain how organ systems can be represented and coupled. A model that is updated repeatedly from patient measurements must also specify when those measurements support a particular conclusion. This Hypothesis and Theory article proposes an Observation Contract Framework: a declared set of evidence requirements for each output, checked whenever that output is requested. Each system uses 10 fields covering target states, direct measurements, proxies, unmeasured states, events, reference measurements, timing, quality failures, prohibited conclusions and measurement readiness. The framework returns permit, degrade or block for each output. Five testable hypotheses address unsupported conclusions, timing errors, missing reference measurements, cross-system dependencies and the distinction between signal reconstruction and state validation. The framework is specified for eight peripheral systems, with central nervous system dependencies explicitly left unobserved. A mathematical oxygen-delivery example explains how system requirements are combined. A small retrospective replay of public critical-care records then illustrates the same rules: a record-based oxygen-delivery proxy can be restricted or withheld as haemoglobin measurements become outdated, while a validated physiological oxygen-delivery claim remains blocked. This replay is an application example, not a clinical validation or a comparative test of the hypotheses. Existing sensors support many bounded measurements, but do not continuously identify regional perfusion, venous capacitance, ventilation–perfusion mismatch, endocrine pulsatility, tissue immune activity or in vivo coagulation potential. The framework complements context-of-use definition, observability and identifiability analysis, model interoperability, verification, validation, and uncertainty quantification. Its purpose is to state what evidence is needed for a conclusion and what must be withheld when that evidence is insufficient.

Authors

Institutions

Publication Details

Journal
Frontiers in Physiology
Published
2026-11-20
DOI
https://doi.org/10.3389/fphys.2026.1947699
Primary Topic
Healthcare Technology and Patient Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Physiological digital twins require cross-system observation contracts

Xingshuo Dong
4 links
Frontiers in Physiology
Healthcare Technology and Patient Monitoring
article

Physiological digital twins require cross-system observation contracts

Xingshuo Dong
article en

Abstract

Whole-body models explain how organ systems can be represented and coupled. A model that is updated repeatedly from patient measurements must also specify when those measurements support a particular conclusion. This Hypothesis and Theory article proposes an Observation Contract Framework: a declared set of evidence requirements for each output, checked whenever that output is requested. Each system uses 10 fields covering target states, direct measurements, proxies, unmeasured states, events, reference measurements, timing, quality failures, prohibited conclusions and measurement readiness. The framework returns permit, degrade or block for each output. Five testable hypotheses address unsupported conclusions, timing errors, missing reference measurements, cross-system dependencies and the distinction between signal reconstruction and state validation. The framework is specified for eight peripheral systems, with central nervous system dependencies explicitly left unobserved. A mathematical oxygen-delivery example explains how system requirements are combined. A small retrospective replay of public critical-care records then illustrates the same rules: a record-based oxygen-delivery proxy can be restricted or withheld as haemoglobin measurements become outdated, while a validated physiological oxygen-delivery claim remains blocked. This replay is an application example, not a clinical validation or a comparative test of the hypotheses. Existing sensors support many bounded measurements, but do not continuously identify regional perfusion, venous capacitance, ventilation–perfusion mismatch, endocrine pulsatility, tissue immune activity or in vivo coagulation potential. The framework complements context-of-use definition, observability and identifiability analysis, model interoperability, verification, validation, and uncertainty quantification. Its purpose is to state what evidence is needed for a conclusion and what must be withheld when that evidence is insufficient.

Frontiers in PhysiologyVol. 17
Chinese PLA General Hospital (CN), Chinese People's Liberation Army (CN)
Healthcare Technology and Patient Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Physiological digital twins require cross-system observation contracts — Xingshuo Dong · Frontiers in Physiology (2026) | TGRS Research Map | TGRS