Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging

Background/Objectives: The measurement of radiotracer uptake in specific organs has potential clinical implications. However, manual delineation is time-consuming. We aimed to evaluate the agreement between manual delineation and automatic segmentation by the artificial intelligence model TotalSegmentator for extraction of standard uptake values (SUVs) from [18F]FDG-PET/CT scans for the aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava. Methods: The aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava were segmented manually by trained physicians and automatically by the TotalSegmentator version 2.4 software, and the correlations between SUV values obtained were assessed. Results: We found good agreement between manually and automatically obtained SUVmean values for the aorta (manual/TotalSegmentator: 2.10/2.11), spleen (2.00/1.95), liver (2.53/2.37), lumbar spine bone marrow (1.88/1.85), and superior vena cava (2.02/1.88) with high correlation coefficients across all organs, ranging from 0.93 to 0.99 and high intraclass correlation coefficients (ICCs) of 0.81–0.99. Agreement for SUVmax showed greater variability across the organs which were assessed: agreement was good for the spleen (ICC 0.83) and lumbar spine bone marrow (ICC 0.86), but weak for the aorta (ICC 0.11). Bland–Altman analyses for SUVmean indicated no systematic bias in the aorta or spleen, slight bias in bone marrow, liver, and superior vena cava, and variable bias for SUVmax across all structures. Conclusions: TotalSegmentator provided reliable SUVmean values from the aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava. However, the agreement between manually and automatically obtained SUVmax values was variable, suggesting that additional quality control steps should be applied if using TotalSegmentator for SUVmax extraction.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-20
DOI
https://doi.org/10.3390/diagnostics16223895
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging

Peter Riis Hansen, Flemming Littrup Andersen, Lene Terslev, Tanja Fromberg Gorlén et al.
1 links
Diagnostics
Medical Image Segmentation Techniques
article

Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging

Peter Riis Hansen, Flemming Littrup Andersen, Lene Terslev, Tanja Fromberg Gorlén, Rasmus Sejersten Ripa, Jane Maestri Brittain, Mikkel Østergaard, Edvin Smajlovic
article en

Abstract

Background/Objectives: The measurement of radiotracer uptake in specific organs has potential clinical implications. However, manual delineation is time-consuming. We aimed to evaluate the agreement between manual delineation and automatic segmentation by the artificial intelligence model TotalSegmentator for extraction of standard uptake values (SUVs) from [18F]FDG-PET/CT scans for the aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava. Methods: The aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava were segmented manually by trained physicians and automatically by the TotalSegmentator version 2.4 software, and the correlations between SUV values obtained were assessed. Results: We found good agreement between manually and automatically obtained SUVmean values for the aorta (manual/TotalSegmentator: 2.10/2.11), spleen (2.00/1.95), liver (2.53/2.37), lumbar spine bone marrow (1.88/1.85), and superior vena cava (2.02/1.88) with high correlation coefficients across all organs, ranging from 0.93 to 0.99 and high intraclass correlation coefficients (ICCs) of 0.81–0.99. Agreement for SUVmax showed greater variability across the organs which were assessed: agreement was good for the spleen (ICC 0.83) and lumbar spine bone marrow (ICC 0.86), but weak for the aorta (ICC 0.11). Bland–Altman analyses for SUVmean indicated no systematic bias in the aorta or spleen, slight bias in bone marrow, liver, and superior vena cava, and variable bias for SUVmax across all structures. Conclusions: TotalSegmentator provided reliable SUVmean values from the aorta, spleen, lumbar spine bone marrow, liver, and superior vena cava. However, the agreement between manually and automatically obtained SUVmax values was variable, suggesting that additional quality control steps should be applied if using TotalSegmentator for SUVmax extraction.

DiagnosticsVol. 16(22)
University of Copenhagen (DK), Herlev Hospital (DK), Bispebjerg Hospital (DK), Glostrup Hospital (DK), Copenhagen University Hospital (DK), Gentofte Hospital (DK), Rigshospitalet (DK)
Gigtforeningen
Good health and well-being
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon