Hydraulic performance and vibration response of a centrifugal pump with a 3D-printed impeller under controlled unbalance conditions

Centrifugal pump performance and reliability can be strongly affected by rotor unbalance, while the increasing use of additive manufacturing raises additional questions related to the dynamic behavior of printed rotating components. This study experimentally investigates the hydraulic performance and vibration response of a centrifugal pump equipped with a fused deposition modeling (FDM) impeller manufactured from polylactic acid (PLA) and subjected to controlled added-mass conditions. The hydraulic performance of the 3D-printed impeller was first compared with that of the original impeller through head–flow rate and vibration measurements, showing similar overall behavior, with an average difference of approximately 4\% between the head–flow rate curves. A controlled unbalance was then introduced by adding masses at a fixed radial position of up to 0.270 g, corresponding to an added unbalance magnitude approximately three times the calculated permissible residual unbalance reference, without removing the impeller from the shaft. Five 15-second vibration measurements were recorded for each condition in both radial and axial directions, and the corresponding power spectral densities (PSD) were analyzed. The vibration response was dominated by the 3X rotational component rather than the expected 1X component. Moreover, the 3X peak PSD amplitude initially decreased with added mass and subsequently increased, which may indicate partial compensation of an existing unbalance of the rotor assembly before additional mass increased the overall unbalance. The dominant 3X response may be associated with structural resonance or the dynamic characteristics of the partially infilled FDM impeller. These results demonstrate the feasibility of using additively manufactured impellers for controlled experimental studies of pump unbalance and vibration behavior.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-20
DOI
https://doi.org/10.21203/rs.3.rs-11625811/v1
Primary Topic
Cavitation Phenomena in Pumps
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Hydraulic performance and vibration response of a centrifugal pump with a 3D-printed impeller under controlled unbalance conditions

L. Enrique Ortiz-Vidal, Daniel Emilio Casagrande, Sebastián Daniel Jeldres Sepúlveda
2 links
Research Square
Cavitation Phenomena in Pumps
preprint

Hydraulic performance and vibration response of a centrifugal pump with a 3D-printed impeller under controlled unbalance conditions

L. Enrique Ortiz-Vidal, Daniel Emilio Casagrande, Sebastián Daniel Jeldres Sepúlveda
preprint en

Abstract

Centrifugal pump performance and reliability can be strongly affected by rotor unbalance, while the increasing use of additive manufacturing raises additional questions related to the dynamic behavior of printed rotating components. This study experimentally investigates the hydraulic performance and vibration response of a centrifugal pump equipped with a fused deposition modeling (FDM) impeller manufactured from polylactic acid (PLA) and subjected to controlled added-mass conditions. The hydraulic performance of the 3D-printed impeller was first compared with that of the original impeller through head–flow rate and vibration measurements, showing similar overall behavior, with an average difference of approximately 4\% between the head–flow rate curves. A controlled unbalance was then introduced by adding masses at a fixed radial position of up to 0.270 g, corresponding to an added unbalance magnitude approximately three times the calculated permissible residual unbalance reference, without removing the impeller from the shaft. Five 15-second vibration measurements were recorded for each condition in both radial and axial directions, and the corresponding power spectral densities (PSD) were analyzed. The vibration response was dominated by the 3X rotational component rather than the expected 1X component. Moreover, the 3X peak PSD amplitude initially decreased with added mass and subsequently increased, which may indicate partial compensation of an existing unbalance of the rotor assembly before additional mass increased the overall unbalance. The dominant 3X response may be associated with structural resonance or the dynamic characteristics of the partially infilled FDM impeller. These results demonstrate the feasibility of using additively manufactured impellers for controlled experimental studies of pump unbalance and vibration behavior.

Research Square
Universidad de O'Higgins (CL), Universidad Tecnológica del Perú (PE)
Agencia Nacional de Investigación y Desarrollo
Cavitation Phenomena in Pumps
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon