An Hb Concentration Measurement Method Based on Multimodal Information Fusion and APSO-SVR

Accurate measurement of hemoglobin (Hb) concentration during hemodialysis is essential for monitoring hemoconcentration and evaluating dialysis effectiveness. Existing optical Hb monitoring methods predominantly rely on single-wavelength signals, which are insufficient to fully characterize the complex optical properties of whole blood. Moreover, their measurement accuracy is susceptible to variations in blood temperature, blood pump flow rate, and scattering characteristics. To address these limitations, this study proposes an Hb concentration measurement method based on multimodal information fusion and adaptive particle swarm optimization–support vector regression (APSO-SVR). To investigate the effects of blood temperature, blood pump flow rate, and scattering variations on optical Hb measurement, the rheological properties and optical responses of blood under different conditions were analyzed, and a dual-wavelength measurement scheme was developed based on the distinct optical responses of blood at 660 nm and 940 nm. Subsequently, dual-wavelength optical features and temperature–flow coupling features were constructed using calibrated photoelectric signals, temperature measurements, and blood pump flow rate information. Pearson correlation coefficient (PCC) analysis and minimum redundancy maximum relevance (mRMR) were applied for feature selection, followed by optimization of the SVR parameters using APSO. The proposed method was then evaluated through experiments involving different combinations of temperature and flow rate conditions and comparisons with other prediction models. The results showed that the APSO-SVR model with selected dual-wavelength features achieved good Hb concentration prediction performance, with a root mean square error (RMSE) of 4.34 g/L and a coefficient of determination (R2) of 0.871. The proposed method improved Hb concentration prediction accuracy under different stabilized experimental conditions, demonstrating its potential for optical Hb monitoring. Further validation under dynamic conditions is required to assess its applicability to continuous monitoring during hemodialysis.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-20
DOI
https://doi.org/10.3390/s26227342
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An Hb Concentration Measurement Method Based on Multimodal Information Fusion and APSO-SVR

Wang Fang, Laihu Peng, Zhuosheng Sun, Xiaodong Wang et al.
Sensors
Optical Imaging and Spectroscopy Techniques
article

An Hb Concentration Measurement Method Based on Multimodal Information Fusion and APSO-SVR

Wang Fang, Laihu Peng, Zhuosheng Sun, Xiaodong Wang, Jianqiang Li, Zexin Zhang
article en

Abstract

Accurate measurement of hemoglobin (Hb) concentration during hemodialysis is essential for monitoring hemoconcentration and evaluating dialysis effectiveness. Existing optical Hb monitoring methods predominantly rely on single-wavelength signals, which are insufficient to fully characterize the complex optical properties of whole blood. Moreover, their measurement accuracy is susceptible to variations in blood temperature, blood pump flow rate, and scattering characteristics. To address these limitations, this study proposes an Hb concentration measurement method based on multimodal information fusion and adaptive particle swarm optimization–support vector regression (APSO-SVR). To investigate the effects of blood temperature, blood pump flow rate, and scattering variations on optical Hb measurement, the rheological properties and optical responses of blood under different conditions were analyzed, and a dual-wavelength measurement scheme was developed based on the distinct optical responses of blood at 660 nm and 940 nm. Subsequently, dual-wavelength optical features and temperature–flow coupling features were constructed using calibrated photoelectric signals, temperature measurements, and blood pump flow rate information. Pearson correlation coefficient (PCC) analysis and minimum redundancy maximum relevance (mRMR) were applied for feature selection, followed by optimization of the SVR parameters using APSO. The proposed method was then evaluated through experiments involving different combinations of temperature and flow rate conditions and comparisons with other prediction models. The results showed that the APSO-SVR model with selected dual-wavelength features achieved good Hb concentration prediction performance, with a root mean square error (RMSE) of 4.34 g/L and a coefficient of determination (R2) of 0.871. The proposed method improved Hb concentration prediction accuracy under different stabilized experimental conditions, demonstrating its potential for optical Hb monitoring. Further validation under dynamic conditions is required to assess its applicability to continuous monitoring during hemodialysis.

SensorsVol. 26(22)
Zhejiang Sci-Tech University (CN)
National Key Research and Development Program of China
Good health and well-being
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon