Chip-integrated superconducting gravimetric sensing via flux-mediated transmon mechanical coupling: Theory and device requirements

Measurements of local gravitational acceleration support geophysics and inertial navigation. We develop a circuit-level model of a chip-integrated superconducting gravimetric sensing head that longitudinally couples a nanomechanical beam in a superconducting quantum interference device (SQUID) loop to an independently flux-biased transmon. The interaction encodes changes in gravitational acceleration in the qubit Ramsey phase. We derive the phase response and evaluate the quantum Fisher information of the reduced qubit state and the classical Fisher information accessible through Ramsey readout. The model includes qubit relaxation and dephasing, mechanical damping, flux noise, readout infidelity, and cycle overhead. With other model inputs fixed, the competition between phase gain and responsivity-dependent decoherence yields a finite optimal transmon frequency responsivity to mechanical-loop flux. The decoherence model includes dephasing from low-frequency flux noise in the mechanical SQUID loop and coupling-dependent qubit dephasing from the mechanical bath. For the prospective integrated-device parameter set, Ramsey readout at the first mechanical revival gives a conditional projection of the sensing head's sensitivity of 1.1×10−5ms−2 Hz−1/2 at an interrogation time of 10.0 μs. This estimate uses the single-cycle-equivalent Fisher-information rate for statistically independent cycles. A separate analysis identifies the joint mechanical, circuit, flux-noise, coherence, timing, and readout parameters needed within the model to reach 10−6-class internal sensitivity. These results specify the design trade-offs and component requirements for Ramsey gravimetry in the proposed SQUID–transmon electromechanical sensing head.

Authors

Institutions

Publication Details

Journal
AVS Quantum Science
Published
2026-11-20
DOI
https://doi.org/10.1116/5.0356589
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Chip-integrated superconducting gravimetric sensing via flux-mediated transmon mechanical coupling: Theory and device requirements

Saif M. Al-Kuwari, Salman Sajad Wani, Abrar Ahmed Naqash, Mughees Ahmed Khan
2 links
AVS Quantum Science
Mechanical and Optical Resonators
article

Chip-integrated superconducting gravimetric sensing via flux-mediated transmon mechanical coupling: Theory and device requirements

Saif M. Al-Kuwari, Salman Sajad Wani, Abrar Ahmed Naqash, Mughees Ahmed Khan
article en

Abstract

Measurements of local gravitational acceleration support geophysics and inertial navigation. We develop a circuit-level model of a chip-integrated superconducting gravimetric sensing head that longitudinally couples a nanomechanical beam in a superconducting quantum interference device (SQUID) loop to an independently flux-biased transmon. The interaction encodes changes in gravitational acceleration in the qubit Ramsey phase. We derive the phase response and evaluate the quantum Fisher information of the reduced qubit state and the classical Fisher information accessible through Ramsey readout. The model includes qubit relaxation and dephasing, mechanical damping, flux noise, readout infidelity, and cycle overhead. With other model inputs fixed, the competition between phase gain and responsivity-dependent decoherence yields a finite optimal transmon frequency responsivity to mechanical-loop flux. The decoherence model includes dephasing from low-frequency flux noise in the mechanical SQUID loop and coupling-dependent qubit dephasing from the mechanical bath. For the prospective integrated-device parameter set, Ramsey readout at the first mechanical revival gives a conditional projection of the sensing head's sensitivity of 1.1×10−5ms−2 Hz−1/2 at an interrogation time of 10.0 μs. This estimate uses the single-cycle-equivalent Fisher-information rate for statistically independent cycles. A separate analysis identifies the joint mechanical, circuit, flux-noise, coherence, timing, and readout parameters needed within the model to reach 10−6-class internal sensitivity. These results specify the design trade-offs and component requirements for Ramsey gravimetry in the proposed SQUID–transmon electromechanical sensing head.

AVS Quantum ScienceVol. 8(4)
Canadian Quantum Research Center (CA), Hamad bin Khalifa University (QA)
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon