Functional Evaluation of Interchangeable Jaw Geometries
This study evaluated the functional use and repeatability of three interchangeable jaw configurations for tensile testing with a Universal Testing Machine. The configurations were straight serrated, cross serrated, and V shaped jaws. Results were summarized for plate specimens, plain reinforcing bars, and deformed reinforcing bars using yield strength, ultimate tensile strength, elongation, and coefficient of variation. For plates, ultimate tensile strength ranged from 400.58 to 523.20 MPa; for plain reinforcing bars, it ranged from 517.52 to 538.43 MPa; and for deformed bars, it ranged from 596.99 to 674.43 MPa. The coefficient of variation of ultimate tensile strength ranged from 0.71% to 3.81% for plates and from 0.10% to 2.56% for reinforcing bars in the reported groups. These results describe performance within the tested specimen categories but do not isolate jaw geometry as a causal factor because specimen form and dimensions differed. Direct slip measurements were unavailable; therefore, the effect of jaw geometry on slip could not be established statistically.
Authors
- Sahat Sahat
- Franklin Taruyun Hudeardo Sinaga
- Jandri Fan HT Saragi
Institutions
- Politeknik Negeri Medan (ID)
Publication Details
- Journal
- Journal La Multiapp
- Published
- 2026-11-20
- DOI
- https://doi.org/10.37899/journallamultiapp.v7i5.6065
- Primary Topic
- Structural Behavior of Reinforced Concrete
- Type
- article
- Field-Weighted Citation Impact
- 0.00