Characterization of random media using diffusion constant: comparison of coherent and incoherent backscattering methods

Within the broader field of quantitative ultrasound (QUS), multiple-scattering approaches provide a complementary framework for characterizing complex tissues or random media where conventional imaging and single-scattering assumptions become unreliable. Measuring the diffusion constant (D) in such media is highly relevant because D is directly related to scatterer density. This study evaluates two complementary techniques for measuring D: Incoherent Backscattering (IBS) and enhanced Coherent Backscattering (eCBS). Using Fullwave numerical simulations and experimental phantom validation, we compare their respective performance. Specifically, the interface between the ultrasound probe and the scattering medium is evaluated across three configurations: direct contact, a water layer, and an inhomogeneous aberrating layer. Our results demonstrate that while far-field measurements introduce significant errors due to diffraction for diverging waves, Gaussian beamforming effectively corrects this bias by refocusing the elements on the scattering medium surface. In contrast, the eCBS method (uses plane waves) is inherently independent of the distance between the probe and the scattering medium. The eCBS method proves more resilient to the phase distortions caused by an aberrating layer, but is limited by a shorter temporal window of phase coherence and is prone to instability in weakly scattering regimes where ballistic waves mask the backscattering cone. The simulations show that IBS provides more fitting samples and a longer usable temporal window than eCBS (40 μs vs. 22 μs), enabling meaningful diffusion measurements over a longer duration. In simulations, eCBS showed smaller deviations from the Direct baseline than IBS in the presence of an aberrating layer (RMSE_eCBS = 0.06, RMSE_IBS = 0.25). Experimentally, eCBS estimates were consistent with the baseline but had large uncertainties (N = 5), so this advantage should be considered preliminary. This work establishes a dual-method framework for selecting the optimal characterization tool based on acoustic environment, bridging the gap between idealized models and realistic configurations.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-11-20
DOI
https://doi.org/10.1088/1361-6560/aec52d
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Characterization of random media using diffusion constant: comparison of coherent and incoherent backscattering methods

Marie M. Muller, S. Gautam, Masashi Sode, Gianmarco Pinton et al.
2 links
Physics in Medicine and Biology
Ultrasound Imaging and Elastography
article

Characterization of random media using diffusion constant: comparison of coherent and incoherent backscattering methods

Marie M. Muller, S. Gautam, Masashi Sode, Gianmarco Pinton, Jonathan Mamou, François Legrand
article en

Abstract

Within the broader field of quantitative ultrasound (QUS), multiple-scattering approaches provide a complementary framework for characterizing complex tissues or random media where conventional imaging and single-scattering assumptions become unreliable. Measuring the diffusion constant (D) in such media is highly relevant because D is directly related to scatterer density. This study evaluates two complementary techniques for measuring D: Incoherent Backscattering (IBS) and enhanced Coherent Backscattering (eCBS). Using Fullwave numerical simulations and experimental phantom validation, we compare their respective performance. Specifically, the interface between the ultrasound probe and the scattering medium is evaluated across three configurations: direct contact, a water layer, and an inhomogeneous aberrating layer. Our results demonstrate that while far-field measurements introduce significant errors due to diffraction for diverging waves, Gaussian beamforming effectively corrects this bias by refocusing the elements on the scattering medium surface. In contrast, the eCBS method (uses plane waves) is inherently independent of the distance between the probe and the scattering medium. The eCBS method proves more resilient to the phase distortions caused by an aberrating layer, but is limited by a shorter temporal window of phase coherence and is prone to instability in weakly scattering regimes where ballistic waves mask the backscattering cone. The simulations show that IBS provides more fitting samples and a longer usable temporal window than eCBS (40 μs vs. 22 μs), enabling meaningful diffusion measurements over a longer duration. In simulations, eCBS showed smaller deviations from the Direct baseline than IBS in the presence of an aberrating layer (RMSE_eCBS = 0.06, RMSE_IBS = 0.25). Experimentally, eCBS estimates were consistent with the baseline but had large uncertainties (N = 5), so this advantage should be considered preliminary. This work establishes a dual-method framework for selecting the optimal characterization tool based on acoustic environment, bridging the gap between idealized models and realistic configurations.

Physics in Medicine and Biology
University of North Carolina at Chapel Hill (US), North Carolina State University (US), Weill Cornell Medicine (US)
National Institutes of Health, National Heart, Lung, and Blood Institute
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon