Hourly Clean Electricity Tracing and Masked Computation Support Enterprise Carbon Certification

Annual and regional emission factors obscure hourly and nodal variation in clean electricity availability. We developed a consumer-side carbon accounting workflow that combines hydropower dispatch, proportional-sharing electricity tracing and masked certification. In a modified IEEE 39-bus system, nodal clean electricity fractions ranged from 2.95 percent to approximately 100 percent, while three constructed industrial consumers had period-total fractions of 1.96–23.70 percent. A fixed Gaussian mask was shared among trustees and removed before release; a smaller hourly perturbation remained. Across 100 Monte Carlo runs, the released estimates had a mean absolute error of 2.200 MW and a period-total absolute error of 36.08 MWh, compared with 9.272 MW and 240.78 MWh for the tested local-noise baseline. The hybrid scheme also had a 49.24 percent mean absolute percentage error and a 9.33 percent clipping rate. These results support finer spatial attribution and lower absolute error under the selected settings, but do not establish a formal differential-privacy guarantee.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-20
DOI
https://doi.org/10.21203/rs.3.rs-11499776/v1
Primary Topic
Smart Grid Security and Resilience
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Hourly Clean Electricity Tracing and Masked Computation Support Enterprise Carbon Certification

Yumin Chen, Lingyu Chen, tianze yu, Junhua Zhao et al.
2 links
Research Square
Smart Grid Security and Resilience
preprint

Hourly Clean Electricity Tracing and Masked Computation Support Enterprise Carbon Certification

Yumin Chen, Lingyu Chen, tianze yu, Junhua Zhao, Xiangxi Duan, Hongli Liu, Han Zhang, Yang Wei
preprint en

Abstract

Annual and regional emission factors obscure hourly and nodal variation in clean electricity availability. We developed a consumer-side carbon accounting workflow that combines hydropower dispatch, proportional-sharing electricity tracing and masked certification. In a modified IEEE 39-bus system, nodal clean electricity fractions ranged from 2.95 percent to approximately 100 percent, while three constructed industrial consumers had period-total fractions of 1.96–23.70 percent. A fixed Gaussian mask was shared among trustees and removed before release; a smaller hourly perturbation remained. Across 100 Monte Carlo runs, the released estimates had a mean absolute error of 2.200 MW and a period-total absolute error of 36.08 MWh, compared with 9.272 MW and 240.78 MWh for the tested local-noise baseline. The hybrid scheme also had a 49.24 percent mean absolute percentage error and a 9.33 percent clipping rate. These results support finer spatial attribution and lower absolute error under the selected settings, but do not establish a formal differential-privacy guarantee.

Research Square
Chinese University of Hong Kong, Shenzhen (CN), State Grid Sichuan Electric Power Corporation (China) (CN)
Climate action, Affordable and clean energy
Smart Grid Security and Resilience
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon