Enhanced Electrolyte Atmospheric Liquid Discharge via Three-Dimensional Synergistic Effect for Trace Multielement Optical Emission Spectrometry

In liquid direct-introduction microplasma optical emission spectrometry (OES) systems, limited energy deposition near the liquid interface restricts the achievement of low detection limits and sensitive multi-element analysis. To address this issue, two pairs of point-discharge (PD) microplasmas were introduced beneath the main electrolyte atmospheric liquid discharge (EALD) channel to construct a square-pyramidal three-dimensional (3D) discharge configuration for the determination of Cd, Zn, Hg, and Pb in environmental and food samples. This configuration enabled multiple discharge units to act on the same solution region from different directions, thereby reconstructing the discharge profile near the liquid interface and expanding the effective emission region and interaction range. The spatial expansion of the emission region was consistent with the enhanced spectral response, while the higher OES responses maintained under equal total input power further supported the contribution of the 3D discharge configuration to the analytical enhancement. Compared with conventional EALD-OES, the proposed 3D-EALD-OES system enhanced the emission intensities of Cd, Zn, Hg, and Pb by factors of 5.4, 3.5, 3.5, and 2.4, respectively. Under optimized conditions, the limits of detection (LODs) were reduced from 0.3, 1.6, 1.5, and 3.9 μg L−1 to 0.08, 0.5, 0.2, and 1.9 μg L−1, respectively, with relative standard deviations below 4%. The accuracy and applicability of the system were validated by the analysis of certified reference materials and real samples. This 3D structural-modulation enhancement strategy provided a feasible pathway for improving the performance of discharge microplasma-driven miniaturized OES systems.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-11-20
DOI
https://doi.org/10.1021/acs.analchem.6c04556
Primary Topic
Atmospheric-Pressure Plasma Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Enhanced Electrolyte Atmospheric Liquid Discharge via Three-Dimensional Synergistic Effect for Trace Multielement Optical Emission Spectrometry

Yong‐Liang Yu, Hao Shen, Jia-Nan Xu, Shuang Liu et al.
5 links
Analytical Chemistry
Atmospheric-Pressure Plasma Applications
article

Enhanced Electrolyte Atmospheric Liquid Discharge via Three-Dimensional Synergistic Effect for Trace Multielement Optical Emission Spectrometry

Yong‐Liang Yu, Hao Shen, Jia-Nan Xu, Shuang Liu, Yi-Hao Xin
article en

Abstract

In liquid direct-introduction microplasma optical emission spectrometry (OES) systems, limited energy deposition near the liquid interface restricts the achievement of low detection limits and sensitive multi-element analysis. To address this issue, two pairs of point-discharge (PD) microplasmas were introduced beneath the main electrolyte atmospheric liquid discharge (EALD) channel to construct a square-pyramidal three-dimensional (3D) discharge configuration for the determination of Cd, Zn, Hg, and Pb in environmental and food samples. This configuration enabled multiple discharge units to act on the same solution region from different directions, thereby reconstructing the discharge profile near the liquid interface and expanding the effective emission region and interaction range. The spatial expansion of the emission region was consistent with the enhanced spectral response, while the higher OES responses maintained under equal total input power further supported the contribution of the 3D discharge configuration to the analytical enhancement. Compared with conventional EALD-OES, the proposed 3D-EALD-OES system enhanced the emission intensities of Cd, Zn, Hg, and Pb by factors of 5.4, 3.5, 3.5, and 2.4, respectively. Under optimized conditions, the limits of detection (LODs) were reduced from 0.3, 1.6, 1.5, and 3.9 μg L−1 to 0.08, 0.5, 0.2, and 1.9 μg L−1, respectively, with relative standard deviations below 4%. The accuracy and applicability of the system were validated by the analysis of certified reference materials and real samples. This 3D structural-modulation enhancement strategy provided a feasible pathway for improving the performance of discharge microplasma-driven miniaturized OES systems.

Analytical Chemistry
China Medical University (CN), Northeastern University (CN)
National Natural Science Foundation of China, Doctoral Start-up Foundation of Liaoning Province, Foundation of Liaoning Province Education Administration
Atmospheric-Pressure Plasma Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon