Patient-specific thyroid computational models and SIMIND Monte Carlo simulations for assessing the accuracy of 131I dosimetry in hyperthyroidism

The aim of this study was to use SIMIND Monte Carlo (MC) simulations together with patient-specific thyroid computational models to assess the accuracy of 131I- activity quantification from planar images and thyroid dosimetry calculations in radiopharmaceutical therapy with [131I] sodium iodide for hyperthyroidism. The methodology integrates two components: (i) patient- specific thyroid computational models of big and medium goitre, generated by processing patient computed tomography scans with 3D Slicer Image computing software; and (ii) a virtual gamma camera created using SIMIND MC code. The modelled Picker Prism 2000 XP gamma camera was used to obtain planar images of the patient- specific thyroid computational models, in which a predefined 131I activity of 1.665 MBq was assigned to the thyroid volume, using a high- energy collimator and a distance thyroid/ detector of 5 cm, as clinically representative imaging conditions. The same acquisition parameters were used to obtain simulated planar images of the Zubal reference phantom and a calibration source, with the aim of quantification. Dosimetry calculations were based on a monocompartmental 131I biodistribution model, assuming a post- administration time of 24 hours, and an effective elimination time of 5.5 days. With the proposed methodological framework, two patient- specific thyroid computational models of goitre have been successfully implemented, yielding with SIMIND MC realistic, patient-morphed thyroid scintigraphies. Thyroid activity was quantified with 3% error for the Zubal phantom and ≤0.4% error for the patient-specific computational models, that propagated without modification to the absorbed dose values. The results showed that self-irradiation absorbed dose in the thyroid strongly depends on the thyroid mass that is considered, exhibiting dose values for the medium- goitre that doubled the values for the big goitre, and slightly varies with the nature of the computational model. The study illustrates the utility of SIMIND MC simulations together with thyroid computational models to estimate the accuracy of the dosimetry calculation that could emerge in a realistic clinical setting and to identify the influence of the image acquisition parameters and the thyroid mass in the calculation accuracy.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Radiation Sciences
Published
2026-11-20
DOI
https://doi.org/10.15392/2319-0612.2026.3138
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Patient-specific thyroid computational models and SIMIND Monte Carlo simulations for assessing the accuracy of 131I dosimetry in hyperthyroidism

Cecilia Y. Chain, Luis Héctor Illanes, Enzo Hilario Aman
Brazilian Journal of Radiation Sciences
Radiopharmaceutical Chemistry and Applications
article

Patient-specific thyroid computational models and SIMIND Monte Carlo simulations for assessing the accuracy of 131I dosimetry in hyperthyroidism

Cecilia Y. Chain, Luis Héctor Illanes, Enzo Hilario Aman
article en

Abstract

The aim of this study was to use SIMIND Monte Carlo (MC) simulations together with patient-specific thyroid computational models to assess the accuracy of 131I- activity quantification from planar images and thyroid dosimetry calculations in radiopharmaceutical therapy with [131I] sodium iodide for hyperthyroidism. The methodology integrates two components: (i) patient- specific thyroid computational models of big and medium goitre, generated by processing patient computed tomography scans with 3D Slicer Image computing software; and (ii) a virtual gamma camera created using SIMIND MC code. The modelled Picker Prism 2000 XP gamma camera was used to obtain planar images of the patient- specific thyroid computational models, in which a predefined 131I activity of 1.665 MBq was assigned to the thyroid volume, using a high- energy collimator and a distance thyroid/ detector of 5 cm, as clinically representative imaging conditions. The same acquisition parameters were used to obtain simulated planar images of the Zubal reference phantom and a calibration source, with the aim of quantification. Dosimetry calculations were based on a monocompartmental 131I biodistribution model, assuming a post- administration time of 24 hours, and an effective elimination time of 5.5 days. With the proposed methodological framework, two patient- specific thyroid computational models of goitre have been successfully implemented, yielding with SIMIND MC realistic, patient-morphed thyroid scintigraphies. Thyroid activity was quantified with 3% error for the Zubal phantom and ≤0.4% error for the patient-specific computational models, that propagated without modification to the absorbed dose values. The results showed that self-irradiation absorbed dose in the thyroid strongly depends on the thyroid mass that is considered, exhibiting dose values for the medium- goitre that doubled the values for the big goitre, and slightly varies with the nature of the computational model. The study illustrates the utility of SIMIND MC simulations together with thyroid computational models to estimate the accuracy of the dosimetry calculation that could emerge in a realistic clinical setting and to identify the influence of the image acquisition parameters and the thyroid mass in the calculation accuracy.

Brazilian Journal of Radiation SciencesVol. 14(4)
Universidad Nacional de La Plata (AR)
Good health and well-being
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon