A Condition Assessment and Decision-Making Model for UHV Transformers Driven by a Domain Knowledge Graph and Multidimensional Capability

To address the challenges of poor data quality, reliance on manual intervention, and coarse evaluation granularity in the operation and maintenance of ultra-high-voltage (UHV) transformers, a condition assessment and decision-making model driven by a domain knowledge graph and multidimensional capability assessment is proposed. First, a collaborative data cleaning framework combining variational mode decomposition (VMD) and stacked denoising autoencoders (SDAEs) is established to reconstruct missing data and correct outliers while retaining signal features. Second, a domain knowledge graph for UHV transformers is constructed using a top-down approach. This graph structurally represents fragmented regulations, expert experience, and equipment ledgers, establishing a semantic network that connects condition parameters, components, and capabilities. Third, a multidimensional capability evaluation system is developed to map condition parameters to five core capabilities: insulation, load, short-circuit withstand, voltage regulation, and self-protection, providing more detailed condition information than a single overall score. Finally, a knowledge-driven diagnostic and decision-making model combines expert-assigned association values using a simplified fusion rule and uses graph relationships to link abnormal events with candidate failure modes and operation and maintenance recommendations. For 11 artificially corrupted samples, VMD–SDAE achieves a root mean square error (RMSE) of 0.1634 μL·L−1 and a mean absolute percentage error (MAPE) of 1.69% compared with 0.3319 μL·L−1 and 3.38% for standalone SDAE. Additional comparisons, ablation experiments, and sensitivity analyses examine the cleaning performance and its limitations. A case study produces condition assessment results consistent with on-site judgments and provides maintenance recommendations with traceable reasoning paths.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-11-20
DOI
https://doi.org/10.3390/pr14223732
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Condition Assessment and Decision-Making Model for UHV Transformers Driven by a Domain Knowledge Graph and Multidimensional Capability

Zhong Yongheng, Tang Zhiguo, Yuwei Wang, Fengxiang Li et al.
Processes
Power Transformer Diagnostics and Insulation
article

A Condition Assessment and Decision-Making Model for UHV Transformers Driven by a Domain Knowledge Graph and Multidimensional Capability

Zhong Yongheng, Tang Zhiguo, Yuwei Wang, Fengxiang Li, Puming Xu
article en

Abstract

To address the challenges of poor data quality, reliance on manual intervention, and coarse evaluation granularity in the operation and maintenance of ultra-high-voltage (UHV) transformers, a condition assessment and decision-making model driven by a domain knowledge graph and multidimensional capability assessment is proposed. First, a collaborative data cleaning framework combining variational mode decomposition (VMD) and stacked denoising autoencoders (SDAEs) is established to reconstruct missing data and correct outliers while retaining signal features. Second, a domain knowledge graph for UHV transformers is constructed using a top-down approach. This graph structurally represents fragmented regulations, expert experience, and equipment ledgers, establishing a semantic network that connects condition parameters, components, and capabilities. Third, a multidimensional capability evaluation system is developed to map condition parameters to five core capabilities: insulation, load, short-circuit withstand, voltage regulation, and self-protection, providing more detailed condition information than a single overall score. Finally, a knowledge-driven diagnostic and decision-making model combines expert-assigned association values using a simplified fusion rule and uses graph relationships to link abnormal events with candidate failure modes and operation and maintenance recommendations. For 11 artificially corrupted samples, VMD–SDAE achieves a root mean square error (RMSE) of 0.1634 μL·L−1 and a mean absolute percentage error (MAPE) of 1.69% compared with 0.3319 μL·L−1 and 3.38% for standalone SDAE. Additional comparisons, ablation experiments, and sensitivity analyses examine the cleaning performance and its limitations. A case study produces condition assessment results consistent with on-site judgments and provides maintenance recommendations with traceable reasoning paths.

ProcessesVol. 14(22)
North China Electric Power University (CN), State Grid Hunan Electric Power Company Limited (CN)
Industry, innovation and infrastructure
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon