Pulsed X-Ray CT with Temporally Aware Reconstruction for Three-Dimensional Endovascular Guidance: Phantom Feasibility Study

Background: Endovascular fluoroscopy provides limited depth information. Projection-level x-ray pulsing and prior-image reconstruction could enable volumetric CT updates from sparse projection data. Purpose: To assess whether pulsed sparse-view CT combined with temporally aware reconstruction could accurately localize robotically manipulated endovascular devices in a phantom. Materials and Methods: We compared true pulsed acquisitions with matched retrospective sparsification (4—180 projections) in a modular phantom. Eight robotically generated device configurations in an anthropomorphic endovascular phantom were scanned with 1248 projections. Data were retrospectively sparsified to 6, 12, 24, 32, and 52 projections and reconstructed using filtered backprojection and a temporally aware prior-image method. Localization errors were measured relative to full-view filtered-backprojection measurements. Analyses were descriptive. Results: Mean CT number differences between true pulsed and matched retrospectively sparsified images were 4.8—6.2 Hounsfield units; corrected standard deviations were 27.5—29.9 Hounsfield units. Sparse-view filtered backprojection obscured device segments at 6 and 12 projections, whereas temporally aware reconstruction depicted both devices at all projection counts. At 6 projections, median centerline, guidewire-tip, and tip-to-vessel-wall errors were 0.82 mm (interquartile range, 0.10 mm), 0.71 mm (0.12 mm), and 0.03 mm (0.28 mm), respectively. All localization errors were below the 0.944-mm reconstructed voxel diagonal. Conclusion: True pulsed and matched retrospectively sparsified acquisitions showed similar CT numbers in a modular phantom. In an anthropomorphic endovascular phantom, temporally aware reconstruction of retrospectively sparsified data localized robotically manipulated devices within one reconstructed voxel diagonal.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-20
DOI
https://doi.org/10.64898/2026.11.18.26368435
Primary Topic
Radiation Dose and Imaging
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Pulsed X-Ray CT with Temporally Aware Reconstruction for Three-Dimensional Endovascular Guidance: Phantom Feasibility Study

Biju Jacob, Nariman Nezami, Eri Haneda, Amir Pourmorteza et al.
2 links
medRxiv
Radiation Dose and Imaging
preprint

Pulsed X-Ray CT with Temporally Aware Reconstruction for Three-Dimensional Endovascular Guidance: Phantom Feasibility Study

Biju Jacob, Nariman Nezami, Eri Haneda, Amir Pourmorteza, Bruno De Man, Zhye Yin, Navid Azimi, Arnaud Brian-Choux, Simon Sharon, Earl Adamy, Eran Cohen, Stephen Araujo
preprint en

Abstract

Background: Endovascular fluoroscopy provides limited depth information. Projection-level x-ray pulsing and prior-image reconstruction could enable volumetric CT updates from sparse projection data. Purpose: To assess whether pulsed sparse-view CT combined with temporally aware reconstruction could accurately localize robotically manipulated endovascular devices in a phantom. Materials and Methods: We compared true pulsed acquisitions with matched retrospective sparsification (4—180 projections) in a modular phantom. Eight robotically generated device configurations in an anthropomorphic endovascular phantom were scanned with 1248 projections. Data were retrospectively sparsified to 6, 12, 24, 32, and 52 projections and reconstructed using filtered backprojection and a temporally aware prior-image method. Localization errors were measured relative to full-view filtered-backprojection measurements. Analyses were descriptive. Results: Mean CT number differences between true pulsed and matched retrospectively sparsified images were 4.8—6.2 Hounsfield units; corrected standard deviations were 27.5—29.9 Hounsfield units. Sparse-view filtered backprojection obscured device segments at 6 and 12 projections, whereas temporally aware reconstruction depicted both devices at all projection counts. At 6 projections, median centerline, guidewire-tip, and tip-to-vessel-wall errors were 0.82 mm (interquartile range, 0.10 mm), 0.71 mm (0.12 mm), and 0.03 mm (0.28 mm), respectively. All localization errors were below the 0.944-mm reconstructed voxel diagonal. Conclusion: True pulsed and matched retrospectively sparsified acquisitions showed similar CT numbers in a modular phantom. In an anthropomorphic endovascular phantom, temporally aware reconstruction of retrospectively sparsified data localized robotically manipulated devices within one reconstructed voxel diagonal.

medRxiv
Emory University (US), Georgetown University (US)
Good health and well-being
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon