Pore-scale heat transfer in structured packed bed with application in high-grade thermal energy storage
In this study, the thermofluid performance of structured packed beds for high-temperature thermal energy storage applications is explored. Simple cubic (SC), body-centered cubic (BCC), and face-centered cubic (FCC) particle arrangements are investigated through pore-scale simulations accounting for conduction, surface radiation, fluid flow, and interstitial heat transfer. Based on the pore-scale simulations, correlations are developed for friction factor ( f k ), radiation-free effective conductivity ( k c ), radiative exchange factor ( F ), and volumetric interstitial heat transfer coefficient ( h v ), allowing the radiative conductivity ( k r ) and overall effective thermal conductivity ( k eff ) to be calculated. The pore-scale results and proposed correlations are further assessed through comparisons with experimental data and established empirical and numerical correlations available in the literature. These correlations are coupled with a one-dimensional two-phase (1D-2P) model to assess the performance of a packed bed of 1.5 m length and 1.0 m diameter, subjected to a daily cycle of 3 h charging, 18 h storage, 1 h discharging, and 2 h idle. Using performance criteria for charging utilization ratio ( UR ≥ 60 % ), normalized thermocline thickness ( δ ∗ ≤ 40 % ), and fan energy penalty ratio ( Φ Ω ≤ 1 % ), suitable particle diameters of approximately 1 cm, 2–3 cm, and 4 cm are identified for SC, BCC, and FCC, respectively, under the investigated operating conditions. The FCC arrangement exhibits particularly favorable performance by combining stronger interstitial heat transfer with attenuated radiative conductivity, making it more tolerant of larger particle diameters while preserving thermal stratification during the storage period. At d p = 4 cm, FCC stores approximately 449 kWh of total thermal energy in the solid phase at the end of charging and delivers 373 kWh during the subsequent one-hour discharge. Furthermore, a complementary screening approach based on h v , k eff , and f k is proposed to identify promising design configurations by assessing trade-offs between thermal performance and fan power without requiring full transient simulations for every case. Although demonstrated here for particle diameter selection, the approach could be extended to other design and operating parameters, provided that the screening benchmarks are adapted to the packing geometry, material properties, operating conditions, and storage duration of the intended application.
Authors
- AGUS PULUNG SASMITO (ORCID: https://orcid.org/0000-0003-3444-8922)
- Leyla Amiri (ORCID: https://orcid.org/0000-0001-6880-1785)
- Hamidreza Ermagan (ORCID: https://orcid.org/0000-0003-1373-8146)
Institutions
- Université de Sherbrooke (CA)
- McGill University (CA)
Publication Details
- Journal
- Journal of Energy Storage
- Published
- 2026-11-20
- DOI
- https://doi.org/10.1016/j.est.2026.125587
- Primary Topic
- Heat and Mass Transfer in Porous Media
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Fonds de recherche du Québec – Nature et technologies