Limited Discrimination of Risk Scores for Right Ventricular Failure After Left Ventricular Assist Device Implantation

Right ventricular failure (RVF) remains a major complication after left ventricular assist device (LVAD) implantation and is associated with increased morbidity and mortality. Multiple preoperative risk scores and hemodynamic parameters have been proposed to predict RVF; however, their generalizability remains uncertain. We performed a retrospective single-center study of 331 patients undergoing centrifugal-flow LVAD implantation between 2011 and 2025, excluding axial-flow devices. Right ventricular failure, defined by Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) criteria, occurred in 105 patients (31.7%). We evaluated established hemodynamic parameters and published risk scores using logistic regression, standalone receiver operating characteristic analysis, calibration assessment, and sensitivity analyses. Although several risk scores, including European Registry for Patients with Mechanical Circulatory Support (EUROMACS), Utah, and STOP-RVF, were associated with RVF, their discriminative performance was modest, with area under the curve values around 0.70. Discrimination remained modest in the HeartMate 3 subgroup and when postoperative right-sided mechanical circulatory support requirement was used as a more objective endpoint. Calibration analyses showed that published risk strata did not consistently reproduce original absolute event rates, and the incremental improvement beyond preoperative models for predicting a dynamic, institution-dependent complication. Center-specific risk awareness and proactive perioperative management strategies may better mitigate RVF risk.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2026-11-20
DOI
https://doi.org/10.1097/mat.0000000000002900
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Limited Discrimination of Risk Scores for Right Ventricular Failure After Left Ventricular Assist Device Implantation

Patrick Hong, Jay D. Pal, Ioannis Dimarakis, Tomoki Sakata et al.
1 links
ASAIO Journal
Mechanical Circulatory Support Devices
article

Limited Discrimination of Risk Scores for Right Ventricular Failure After Left Ventricular Assist Device Implantation

Patrick Hong, Jay D. Pal, Ioannis Dimarakis, Tomoki Sakata, Kent Shively
article en

Abstract

Right ventricular failure (RVF) remains a major complication after left ventricular assist device (LVAD) implantation and is associated with increased morbidity and mortality. Multiple preoperative risk scores and hemodynamic parameters have been proposed to predict RVF; however, their generalizability remains uncertain. We performed a retrospective single-center study of 331 patients undergoing centrifugal-flow LVAD implantation between 2011 and 2025, excluding axial-flow devices. Right ventricular failure, defined by Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) criteria, occurred in 105 patients (31.7%). We evaluated established hemodynamic parameters and published risk scores using logistic regression, standalone receiver operating characteristic analysis, calibration assessment, and sensitivity analyses. Although several risk scores, including European Registry for Patients with Mechanical Circulatory Support (EUROMACS), Utah, and STOP-RVF, were associated with RVF, their discriminative performance was modest, with area under the curve values around 0.70. Discrimination remained modest in the HeartMate 3 subgroup and when postoperative right-sided mechanical circulatory support requirement was used as a more objective endpoint. Calibration analyses showed that published risk strata did not consistently reproduce original absolute event rates, and the incremental improvement beyond preoperative models for predicting a dynamic, institution-dependent complication. Center-specific risk awareness and proactive perioperative management strategies may better mitigate RVF risk.

ASAIO Journal
University of Washington Medical Center (US)
Good health and well-being
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon