Coupling effects of wind speed and humidity on outdoor thermal comfort: A field study in Xi'an, China

Outdoor airflow is an important microclimatic factor influencing thermal comfort outside buildings, but its cooling effectiveness may be limited under humid conditions. Based on 1056 paired questionnaire responses and microclimatic measurements collected from four outdoor campus spaces in Xi’an, China, this study investigated the coupled effects of wind speed and relative humidity on human thermal sensation and thermal comfort in outdoor environments. Modified Physiologically Equivalent Temperature (MPET), Mean Thermal Sensation Vote (MTSV), and Mean Thermal Comfort Vote (MTCV) were used to evaluate thermal responses. The results reveal three distinct wind–humidity response regimes. In the Synergy Zone (30–45% RH), increasing wind speed was consistently associated with reduced thermal sensation and improved comfort, indicating effective natural outdoor cooling. In the Transition Zone (45–60% RH), the effect of airflow became less stable and was increasingly influenced by background thermal load. When RH exceeded 60% and MPET was above approximately 33 °C, a Suppression Zone emerged, in which additional airflow provided limited thermal relief and, in some cases, intensified heat sensation. This phenomenon may be attributed to reduced evaporative potential and increased skin wettedness under humid conditions. The results also indicate that physiological thermal sensation and psychological comfort do not always change in parallel under high humidity. Overall, the findings support a threshold-based understanding of wind–humidity interactions in outdoor thermal comfort assessment, suggesting that wind-related outdoor cooling effects should be evaluated dynamically according to humidity conditions rather than by simply increasing airflow intensity.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2026-11-20
DOI
https://doi.org/10.1016/j.egyr.2026.109764
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Coupling effects of wind speed and humidity on outdoor thermal comfort: A field study in Xi'an, China

Ying Li
2 links
Energy Reports
Urban Heat Island Mitigation
article

Coupling effects of wind speed and humidity on outdoor thermal comfort: A field study in Xi'an, China

Ying Li
article en

Abstract

Outdoor airflow is an important microclimatic factor influencing thermal comfort outside buildings, but its cooling effectiveness may be limited under humid conditions. Based on 1056 paired questionnaire responses and microclimatic measurements collected from four outdoor campus spaces in Xi’an, China, this study investigated the coupled effects of wind speed and relative humidity on human thermal sensation and thermal comfort in outdoor environments. Modified Physiologically Equivalent Temperature (MPET), Mean Thermal Sensation Vote (MTSV), and Mean Thermal Comfort Vote (MTCV) were used to evaluate thermal responses. The results reveal three distinct wind–humidity response regimes. In the Synergy Zone (30–45% RH), increasing wind speed was consistently associated with reduced thermal sensation and improved comfort, indicating effective natural outdoor cooling. In the Transition Zone (45–60% RH), the effect of airflow became less stable and was increasingly influenced by background thermal load. When RH exceeded 60% and MPET was above approximately 33 °C, a Suppression Zone emerged, in which additional airflow provided limited thermal relief and, in some cases, intensified heat sensation. This phenomenon may be attributed to reduced evaporative potential and increased skin wettedness under humid conditions. The results also indicate that physiological thermal sensation and psychological comfort do not always change in parallel under high humidity. Overall, the findings support a threshold-based understanding of wind–humidity interactions in outdoor thermal comfort assessment, suggesting that wind-related outdoor cooling effects should be evaluated dynamically according to humidity conditions rather than by simply increasing airflow intensity.

Energy ReportsVol. 16
Xi'an Fanyi University (CN)
Climate action
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Coupling effects of wind speed and humidity on outdoor thermal comfort: A field study in Xi'an, China — Ying Li · Energy Reports (2026) | TGRS Research Map | TGRS