HESSIAN-FREE FLUX OPTIMIZATION FOR ENERGY-EFFICIENT INDUCTION MOTOR DRIVES: EXPERIMENTAL VALIDATION

Conventional field-oriented control (FOC) of induction motor drives typically employs a fixed flux reference, leading to reduced energy efficiency, particularly under light-load conditions due to excessive excitation and increased losses. To address this limitation, this paper proposes a lightweight Hessian-free adaptive flux optimization strategy. A simple real-time update law for the d-axis current is developed, enabling effective loss minimization without requiring second-order derivative computation, iterative optimization, or additional hardware. By capturing the nonlinear coupling between torque demand and excitation, the method dynamically adjusts the flux while preserving the conventional FOC structure. Experimental results demonstrate significant efficiency improvement over a wide operating range, with efficiency increasing from 31.02% to 61.87% under light-load conditions and from 69.07% to 77.61% at rated load compared to conventional PI-based FOC. The proposed approach provides a low-complexity solution suitable for real-time industrial applications.

Authors

Institutions

Publication Details

Journal
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Published
2026-11-20
DOI
https://doi.org/10.59277/rrst-ee.2026.4.1
Primary Topic
Sensorless Control of Electric Motors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

HESSIAN-FREE FLUX OPTIMIZATION FOR ENERGY-EFFICIENT INDUCTION MOTOR DRIVES: EXPERIMENTAL VALIDATION

Ngoc Thuy Pham
2 links
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Sensorless Control of Electric Motors
article

HESSIAN-FREE FLUX OPTIMIZATION FOR ENERGY-EFFICIENT INDUCTION MOTOR DRIVES: EXPERIMENTAL VALIDATION

Ngoc Thuy Pham
article en

Abstract

Conventional field-oriented control (FOC) of induction motor drives typically employs a fixed flux reference, leading to reduced energy efficiency, particularly under light-load conditions due to excessive excitation and increased losses. To address this limitation, this paper proposes a lightweight Hessian-free adaptive flux optimization strategy. A simple real-time update law for the d-axis current is developed, enabling effective loss minimization without requiring second-order derivative computation, iterative optimization, or additional hardware. By capturing the nonlinear coupling between torque demand and excitation, the method dynamically adjusts the flux while preserving the conventional FOC structure. Experimental results demonstrate significant efficiency improvement over a wide operating range, with efficiency increasing from 31.02% to 61.87% under light-load conditions and from 69.07% to 77.61% at rated load compared to conventional PI-based FOC. The proposed approach provides a low-complexity solution suitable for real-time industrial applications.

REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUEVol. 71(4)
Industrial University of Ho Chi Minh City (VN)
Affordable and clean energy, Industry, innovation and infrastructure
Sensorless Control of Electric Motors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
HESSIAN-FREE FLUX OPTIMIZATION FOR ENERGY-EFFICIENT INDUCTION MOTOR DRIVES: EXPERIMENTAL VALIDATION — Ngoc Thuy Pham · REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE (2026) | TGRS Research Map | TGRS