Sensitivity-oriented fusion of resting ECGs and structured CCTA reports for identifying angiography-defined severe right coronary artery stenosis: a single-centre retrospective study
Background: Failure to identify severe right coronary artery (RCA) stenosis may delay invasive assessment and treatment planning. Structured coronary computed tomography angiography (CCTA) reports provide anatomical screening information, but report-derived stenosis summaries do not capture electrophysiological consequences. We fused resting 12-lead electrocardiograms (ECGs) with structured CCTA report features in a multimodal model. We then evaluated sensitivity-oriented identification of RCA diameter stenosis of at least 70% in coronary angiography (CAG) reports. Results: This single-centre retrospective study included 1,904 ECG records from 760 patients who underwent ECG, CCTA, and CAG. CAG reports provided the reference labels. The model combined a one-dimensional residual network, axial multi-head self-attention, lead attention, and feature-wise linear modulation by report-derived stenosis features from four coronary arteries. Performance was estimated using internal patient-grouped fivefold cross-validation. At the patient level, the multimodal model achieved sensitivity of 0.849±0.037 and specificity of 0.690±0.037. Its area under the receiver operating characteristic curve (AUC) was 0.831±0.020, with accuracy of 0.764±0.028 and F1 score of 0.761±0.051. The structured-report model achieved an AUC of 0.794, sensitivity of 0.391, and specificity of 0.837. Thus, multimodal fusion increased sensitivity while reducing specificity. The ECG-only model achieved an AUC of 0.574. Ablation analyses associated CCTA fusion, temporal-decay weighting, and attention modules with internal performance. An ancillary post hoc analysis reclassified 38 of 66 CCTA false-positive patients as negative, but it did not establish clinical net benefit. Conclusions: In this selected single-centre cohort, ECG and structured CCTA report fusion produced a high-sensitivity operating profile for angiography-defined severe RCA stenosis, with a corresponding reduction in specificity. The model may warrant evaluation as a sensitivity-oriented secondary screening aid, but it cannot yet be used to rule out disease or claim prevention of missed diagnoses. Independent multicentre validation, prespecified threshold locking, calibration, and prospective clinical-utility assessment are required before implementation.
Authors
- Shenqi Jing (ORCID: https://orcid.org/0000-0002-8529-0566)
- Tao Shan (ORCID: https://orcid.org/0000-0001-6282-656X)
- Yue He
- Yong Li
- Qiuyang Yang
- Yun Liu
Institutions
- Nanjing University of Posts and Telecommunications (CN)
- Jiangsu Province Hospital (CN)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-20
- DOI
- https://doi.org/10.21203/rs.3.rs-10387984/v1
- Primary Topic
- ECG Monitoring and Analysis
- Type
- preprint
Funders
- Nanjing Medical University
- National Key Research and Development Program of China