Need for removal of flexible intramedullary nails used to treat femoral shaft fractures in children: an observational study of 55 children with a minimum of 5-year follow-up

BACKGROUND AND PURPOSE: Removal of flexible intramedullary nails (FIN) in children with femoral shaft fractures has been considered unnecessary when nails are left unbent flush to the bone. We aimed to evaluate the frequency and timing of nail removal on demand. METHODS: This is an observational follow-up study including consecutive 3-14-year-old children with femoral shaft fractures treated during 2011-2018 with FIN. The instruction was to leave the distal ends of the nails unbent above the distal femoral physis. Alignment of the fracture and position of the nails were assessed after nailing and during follow-up. Data on nail removal rates and timing was collected with at least 5 years of follow-up. The outcomes for children with correctly placed nails were compared with those with nails that were too long, defined as cut at or below the distal femoral physis evaluated from postoperative radiographs. RESULTS: 55 consecutive children were included. All fractures healed in satisfactory alignment. FINs were too long in 24 patients (20 distally, 4 proximally). Hardware was removed in 37 (67%) children at a median of 2.4 years from surgery because of pain (range 0.3-9.3). Removal occurred in 21/24 of those with too long nails, and in 16/31 patients with correctly applied FIN, RR 1.7 (95% confidence interval 1.2-2.5, P = 0.005). CONCLUSION: Half of the children with unbent FIN placed flush to the bone in femoral shaft fractures had removal of nails. Extending the nail to or below the distal femoral growth plate leads to hardware removal in nearly all cases, mainly due to pain.

Authors

Institutions

Publication Details

Journal
Acta Orthopaedica
Published
2026-11-20
DOI
https://doi.org/10.2340/17453674.2026.47063
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Need for removal of flexible intramedullary nails used to treat femoral shaft fractures in children: an observational study of 55 children with a minimum of 5-year follow-up

Topi Laaksonen, Yrjänä A. Nietosvaara, Ilkka J. Helenius, Kosola Jussi et al.
Acta Orthopaedica
Bone fractures and treatments
article

Need for removal of flexible intramedullary nails used to treat femoral shaft fractures in children: an observational study of 55 children with a minimum of 5-year follow-up

Topi Laaksonen, Yrjänä A. Nietosvaara, Ilkka J. Helenius, Kosola Jussi, Nicolas Robert Nietosvaara, Jani Puhakka
article en

Abstract

BACKGROUND AND PURPOSE: Removal of flexible intramedullary nails (FIN) in children with femoral shaft fractures has been considered unnecessary when nails are left unbent flush to the bone. We aimed to evaluate the frequency and timing of nail removal on demand. METHODS: This is an observational follow-up study including consecutive 3-14-year-old children with femoral shaft fractures treated during 2011-2018 with FIN. The instruction was to leave the distal ends of the nails unbent above the distal femoral physis. Alignment of the fracture and position of the nails were assessed after nailing and during follow-up. Data on nail removal rates and timing was collected with at least 5 years of follow-up. The outcomes for children with correctly placed nails were compared with those with nails that were too long, defined as cut at or below the distal femoral physis evaluated from postoperative radiographs. RESULTS: 55 consecutive children were included. All fractures healed in satisfactory alignment. FINs were too long in 24 patients (20 distally, 4 proximally). Hardware was removed in 37 (67%) children at a median of 2.4 years from surgery because of pain (range 0.3-9.3). Removal occurred in 21/24 of those with too long nails, and in 16/31 patients with correctly applied FIN, RR 1.7 (95% confidence interval 1.2-2.5, P = 0.005). CONCLUSION: Half of the children with unbent FIN placed flush to the bone in femoral shaft fractures had removal of nails. Extending the nail to or below the distal femoral growth plate leads to hardware removal in nearly all cases, mainly due to pain.

Acta OrthopaedicaVol. 97
University of Helsinki (FI), University of Eastern Finland (FI), Helsinki University Hospital (FI), Helsinki Children's Hospital (FI), Schulthess-Klinik (CH), Kanta-Hämeen Keskussairaala (FI), Päijät-Hämeen Keskussairaala (FI)
Good health and well-being
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon