The Association of Fragmented QRS on Electrocardiography With Cardiovascular Events and Mortality in Hemodialysis Patients

INTRODUCTION: Fragmented QRS on 12-lead electrocardiography (ECG) is a marker of myocardial fibrosis, but its clinical significance in hemodialysis patients remains poorly characterized. We evaluated the prevalence of fragmented QRS on the baseline ECG and its association with cardiovascular events and all-cause mortality. METHODS: This retrospective cohort study included 101 patients with end-stage renal disease who started hemodialysis at a tertiary center between 2008 and 2020 (mean follow-up 132 ± 102 months). Fragmented QRS was defined per Das et al. CRITERIA: To avoid immortal time bias, exposure was defined using the baseline ECG only. Cardiovascular events were analyzed by multivariable logistic regression adjusted for prespecified clinical covariates and mortality by Cox regression. FINDINGS: The mean age was 70.9 ± 12.6 years and 63 patients (62.4%) were male. Baseline fragmented QRS was present in 28 patients (27.7%). These patients had a higher prevalence of coronary artery disease (57.1% vs. 28.2%, p = 0.007), lower sodium (136 ± 3.7 vs. 139 ± 3.6 mmol/L, p = 0.001), lower ferritin (476 ± 545 vs. 726 ± 582 ng/mL, p = 0.023), and lower left ventricular ejection fraction (53.4% ± 12.8% vs. 60.1% ± 6.1%, p = 0.024). Cardiovascular events occurred in 43 patients (42.6%) and were more frequent with baseline fragmented QRS (75.0% vs. 30.1%, p < 0.001). After adjustment for age, sex, hypertension, diabetes mellitus, coronary artery disease, and dialysis duration, baseline fragmented QRS remained independently associated with cardiovascular events (odds ratio 10.9, 95% CI 2.33-50.6, p = 0.002). All-cause mortality occurred in 32 patients (31.7%) and was not associated with baseline fragmented QRS (age- and sex-adjusted hazard ratio 1.14, 95% CI 0.54-2.44, p = 0.730). DISCUSSION: Baseline fragmented QRS was common in hemodialysis patients and was independently associated with cardiovascular events, but not with all-cause mortality. Given that ECG is readily available, noninvasive, and inexpensive, fragmented QRS may serve as a useful risk marker; however, larger prospective studies are needed before routine implementation.

Authors

Institutions

Publication Details

Journal
Hemodialysis International
Published
2026-11-20
DOI
https://doi.org/10.1111/hdi.70131
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Association of Fragmented QRS on Electrocardiography With Cardiovascular Events and Mortality in Hemodialysis Patients

Dayimi Kaya, Mehmet Ası Oktan, Aykut Sifil, Cihan Heybeli et al.
1 links
Hemodialysis International
Cardiac electrophysiology and arrhythmias
article

The Association of Fragmented QRS on Electrocardiography With Cardiovascular Events and Mortality in Hemodialysis Patients

Dayimi Kaya, Mehmet Ası Oktan, Aykut Sifil, Cihan Heybeli, Günkut Arslan
article en

Abstract

INTRODUCTION: Fragmented QRS on 12-lead electrocardiography (ECG) is a marker of myocardial fibrosis, but its clinical significance in hemodialysis patients remains poorly characterized. We evaluated the prevalence of fragmented QRS on the baseline ECG and its association with cardiovascular events and all-cause mortality. METHODS: This retrospective cohort study included 101 patients with end-stage renal disease who started hemodialysis at a tertiary center between 2008 and 2020 (mean follow-up 132 ± 102 months). Fragmented QRS was defined per Das et al. CRITERIA: To avoid immortal time bias, exposure was defined using the baseline ECG only. Cardiovascular events were analyzed by multivariable logistic regression adjusted for prespecified clinical covariates and mortality by Cox regression. FINDINGS: The mean age was 70.9 ± 12.6 years and 63 patients (62.4%) were male. Baseline fragmented QRS was present in 28 patients (27.7%). These patients had a higher prevalence of coronary artery disease (57.1% vs. 28.2%, p = 0.007), lower sodium (136 ± 3.7 vs. 139 ± 3.6 mmol/L, p = 0.001), lower ferritin (476 ± 545 vs. 726 ± 582 ng/mL, p = 0.023), and lower left ventricular ejection fraction (53.4% ± 12.8% vs. 60.1% ± 6.1%, p = 0.024). Cardiovascular events occurred in 43 patients (42.6%) and were more frequent with baseline fragmented QRS (75.0% vs. 30.1%, p < 0.001). After adjustment for age, sex, hypertension, diabetes mellitus, coronary artery disease, and dialysis duration, baseline fragmented QRS remained independently associated with cardiovascular events (odds ratio 10.9, 95% CI 2.33-50.6, p = 0.002). All-cause mortality occurred in 32 patients (31.7%) and was not associated with baseline fragmented QRS (age- and sex-adjusted hazard ratio 1.14, 95% CI 0.54-2.44, p = 0.730). DISCUSSION: Baseline fragmented QRS was common in hemodialysis patients and was independently associated with cardiovascular events, but not with all-cause mortality. Given that ECG is readily available, noninvasive, and inexpensive, fragmented QRS may serve as a useful risk marker; however, larger prospective studies are needed before routine implementation.

Hemodialysis International
Dokuz Eylül University (TR)
Good health and well-being
Cardiac electrophysiology and arrhythmias
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon