Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise

Continuous monitoring of heart rate (HR) and core temperature ( $$T_c$$ ) is essential for optimizing athletic performance and preventing heat-related illness. However, traditional monitoring methods like chest straps and wrist-worn trackers often face accuracy challenges during exercise due to sweat, motion, and signal interference. Furthermore, few devices offer validated, synchronized HR and $$T_c$$ monitoring during physical exertion. This study validates the MOMENTUM Sport (MSPORT) earbud, a novel multisensor wearable for synchronized HR and $$T_c$$ tracking and investigates its utility in non-invasive blood lactate prediction. Thirty-six healthy adults (19 males, 17 females) performed an incremental cycling ramp test under controlled laboratory conditions. MSPORT HR and $$T_c$$ were validated against Polar H10 and Braun ThermoScan 7 references. Predictive lactate modeling was implemented via a Leave-One-Subject-Out (LOSO) framework, with physiological significance assessed through Linear Mixed Models (LMM) and temporal coupling via cross-correlation analysis. MSPORT showed good inter-device agreement for HR (MAE: 0.89 bpm; RMSE: 1.10 bpm) compared to the Polar H10, and good ear-canal temperature agreement with the Braun ThermoScan 7 (MAE: 0.35 $$^{\circ }$$ C; MAPE: 0.92%). The lactate prediction model achieved a correlation of $$R = 0.84$$ ( $$p < 0.05$$ ), with LMM confirming $$T_c$$ as a highly significant independent predictor ( $$\beta = 11.63$$ , SE = 1.00, $$z = 11.65$$ , $$p < 0.001$$ , 95% CI [9.68, 13.59]), while HR also contributed significantly ( $$\beta = -1.94$$ , SE = 0.29, $$z = -6.78$$ , $$p < 0.001$$ ). The negative HR coefficient likely reflects collinearity or a suppression effect: once cumulative $$\Delta T_c$$ accounts for the metabolic trend, HR becomes a corrective term. Sex was a significant covariate ( $$\beta = -1.25$$ , $$z = -2.00$$ , $$p = 0.046$$ ). The random intercept variance was 1.909, indicating substantial between-participant variability in baseline lactate (model converged; REML). An exploratory cross-correlation analysis suggested a preliminary temporal association between lactate and ear-canal temperature; the precise lag magnitude cannot be reliably estimated from three-minute lactate sampling intervals. Absolute lactate magnitude showed significant sex-based differences ( $$p < 0.05$$ ). The MSPORT earbud provides reliable HR tracking and good ear-canal temperature agreement with a co-located tympanic reference during laboratory cycling. The exploratory lactate model demonstrates group-level association ( $$R = 0.84$$ ) and supports the feasibility of thermal-cardiac signal fusion for metabolic monitoring, though individual-level accuracy remains insufficient for clinical use. Further research is required to assess performance across diverse exercise protocols, environments, and populations.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-20
DOI
https://doi.org/10.1038/s41598-026-80803-8
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise

Incinur Zellhuber, Martin Schönfelder, Camargo David, Michael Weber
3 links
Scientific Reports
Non-Invasive Vital Sign Monitoring
article

Assessment of the MOMENTUM sport earbud for multi-parametric physiological tracking and exploratory lactate modeling during incremental exercise

Incinur Zellhuber, Martin Schönfelder, Camargo David, Michael Weber
article en

Abstract

Continuous monitoring of heart rate (HR) and core temperature ( $$T_c$$ ) is essential for optimizing athletic performance and preventing heat-related illness. However, traditional monitoring methods like chest straps and wrist-worn trackers often face accuracy challenges during exercise due to sweat, motion, and signal interference. Furthermore, few devices offer validated, synchronized HR and $$T_c$$ monitoring during physical exertion. This study validates the MOMENTUM Sport (MSPORT) earbud, a novel multisensor wearable for synchronized HR and $$T_c$$ tracking and investigates its utility in non-invasive blood lactate prediction. Thirty-six healthy adults (19 males, 17 females) performed an incremental cycling ramp test under controlled laboratory conditions. MSPORT HR and $$T_c$$ were validated against Polar H10 and Braun ThermoScan 7 references. Predictive lactate modeling was implemented via a Leave-One-Subject-Out (LOSO) framework, with physiological significance assessed through Linear Mixed Models (LMM) and temporal coupling via cross-correlation analysis. MSPORT showed good inter-device agreement for HR (MAE: 0.89 bpm; RMSE: 1.10 bpm) compared to the Polar H10, and good ear-canal temperature agreement with the Braun ThermoScan 7 (MAE: 0.35 $$^{\circ }$$ C; MAPE: 0.92%). The lactate prediction model achieved a correlation of $$R = 0.84$$ ( $$p < 0.05$$ ), with LMM confirming $$T_c$$ as a highly significant independent predictor ( $$\beta = 11.63$$ , SE = 1.00, $$z = 11.65$$ , $$p < 0.001$$ , 95% CI [9.68, 13.59]), while HR also contributed significantly ( $$\beta = -1.94$$ , SE = 0.29, $$z = -6.78$$ , $$p < 0.001$$ ). The negative HR coefficient likely reflects collinearity or a suppression effect: once cumulative $$\Delta T_c$$ accounts for the metabolic trend, HR becomes a corrective term. Sex was a significant covariate ( $$\beta = -1.25$$ , $$z = -2.00$$ , $$p = 0.046$$ ). The random intercept variance was 1.909, indicating substantial between-participant variability in baseline lactate (model converged; REML). An exploratory cross-correlation analysis suggested a preliminary temporal association between lactate and ear-canal temperature; the precise lag magnitude cannot be reliably estimated from three-minute lactate sampling intervals. Absolute lactate magnitude showed significant sex-based differences ( $$p < 0.05$$ ). The MSPORT earbud provides reliable HR tracking and good ear-canal temperature agreement with a co-located tympanic reference during laboratory cycling. The exploratory lactate model demonstrates group-level association ( $$R = 0.84$$ ) and supports the feasibility of thermal-cardiac signal fusion for metabolic monitoring, though individual-level accuracy remains insufficient for clinical use. Further research is required to assess performance across diverse exercise protocols, environments, and populations.

Scientific ReportsVol. 16(1)
Technical University of Munich (DE)
Technische Universität München
Good health and well-being
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon