Planning evaluation of 3 photon techniques for hippocampus and scalp sparing WBRT with simultaneous integrated boost in multiple metastases

This study compared the dosimetric and radiobiological parameters of 3 photon beam techniques - 6 megavoltage (MV) flattening filter-free (6XFFF), 6 MV flattened (6XFF), and 10 MV flattened (10XFF) - in hippocampus and scalp sparing whole-brain radiotherapy with simultaneous integrated boost for multiple brain metastases. Twenty-two patients with multiple brain metastases underwent volumetric modulated arc therapy planning using 6XFFF, 6XFF, and 10XFF beams. All plans adhered to Radiation Therapy Oncology Group 0933 constraints for hippocampal avoidance and scalp sparing. Target coverage was evaluated using parameters such as V50 ≥ 95% for planning gross tumor volume and V30 ≥ 90% for planning target volume of the brain. Dosimetric parameters for organs at risk, including the hippocampus and scalp, were analyzed. Radiobiological evaluation included tumor control probability and normal tissue complication probability. Delivery efficiency was assessed using monitor units and control points. All 3 techniques achieved comparable target coverage with no significant differences in dose distribution (P > .05). The 10XFF plan tended to reduce scalp doses (mean Dmax = 31.18 ± 5.4 Gy; Dmean = 15.30 ± 1.23 Gy) compared to 6XFF and 6XFFF, though the differences were not statistically significant (P > .05). Normal tissue complication probability for the hippocampus and tumor control probability for targets were similar across techniques. Delivery efficiency was superior for flattened beams, with the 10XFF plan requiring significantly fewer monitor units (1277.81 ± 178.87) and control points (367.40 ± 19.53) than the 6XFFF plan (P < .001). All 3 techniques provided clinically acceptable target coverage while effectively sparing the hippocampus and scalp. The 10 MV flattened photon beam showed a trend toward reduced scalp irradiation and improved delivery efficiency, suggesting its potential utility when scalp preservation or workflow efficiency is prioritized. Further prospective studies are warranted to validate these findings.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2026-11-20
DOI
https://doi.org/10.1097/md.0000000000051600
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Planning evaluation of 3 photon techniques for hippocampus and scalp sparing WBRT with simultaneous integrated boost in multiple metastases

Minzhi Zhong, Z Chen, Huaqu Zeng, 央幸 林 et al.
2 links
Medicine
Advanced Radiotherapy Techniques
article

Planning evaluation of 3 photon techniques for hippocampus and scalp sparing WBRT with simultaneous integrated boost in multiple metastases

Minzhi Zhong, Z Chen, Huaqu Zeng, 央幸 林, Shukui Tang, Ming Chen, Zunbei Wen, Zhen Li, Yuanyuan Chen, Qifu Lin
article en

Abstract

This study compared the dosimetric and radiobiological parameters of 3 photon beam techniques - 6 megavoltage (MV) flattening filter-free (6XFFF), 6 MV flattened (6XFF), and 10 MV flattened (10XFF) - in hippocampus and scalp sparing whole-brain radiotherapy with simultaneous integrated boost for multiple brain metastases. Twenty-two patients with multiple brain metastases underwent volumetric modulated arc therapy planning using 6XFFF, 6XFF, and 10XFF beams. All plans adhered to Radiation Therapy Oncology Group 0933 constraints for hippocampal avoidance and scalp sparing. Target coverage was evaluated using parameters such as V50 ≥ 95% for planning gross tumor volume and V30 ≥ 90% for planning target volume of the brain. Dosimetric parameters for organs at risk, including the hippocampus and scalp, were analyzed. Radiobiological evaluation included tumor control probability and normal tissue complication probability. Delivery efficiency was assessed using monitor units and control points. All 3 techniques achieved comparable target coverage with no significant differences in dose distribution (P > .05). The 10XFF plan tended to reduce scalp doses (mean Dmax = 31.18 ± 5.4 Gy; Dmean = 15.30 ± 1.23 Gy) compared to 6XFF and 6XFFF, though the differences were not statistically significant (P > .05). Normal tissue complication probability for the hippocampus and tumor control probability for targets were similar across techniques. Delivery efficiency was superior for flattened beams, with the 10XFF plan requiring significantly fewer monitor units (1277.81 ± 178.87) and control points (367.40 ± 19.53) than the 6XFFF plan (P < .001). All 3 techniques provided clinically acceptable target coverage while effectively sparing the hippocampus and scalp. The 10 MV flattened photon beam showed a trend toward reduced scalp irradiation and improved delivery efficiency, suggesting its potential utility when scalp preservation or workflow efficiency is prioritized. Further prospective studies are warranted to validate these findings.

MedicineVol. 105(47)
Zhongshan People's Hospital (CN), Sun Yat-sen University Cancer Center (CN), Gaozhou People's Hospital (CN)
Good health and well-being
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon