Planning evaluation of 3 photon techniques for hippocampus and scalp sparing WBRT with simultaneous integrated boost in multiple metastases
This study compared the dosimetric and radiobiological parameters of 3 photon beam techniques - 6 megavoltage (MV) flattening filter-free (6XFFF), 6 MV flattened (6XFF), and 10 MV flattened (10XFF) - in hippocampus and scalp sparing whole-brain radiotherapy with simultaneous integrated boost for multiple brain metastases. Twenty-two patients with multiple brain metastases underwent volumetric modulated arc therapy planning using 6XFFF, 6XFF, and 10XFF beams. All plans adhered to Radiation Therapy Oncology Group 0933 constraints for hippocampal avoidance and scalp sparing. Target coverage was evaluated using parameters such as V50 ≥ 95% for planning gross tumor volume and V30 ≥ 90% for planning target volume of the brain. Dosimetric parameters for organs at risk, including the hippocampus and scalp, were analyzed. Radiobiological evaluation included tumor control probability and normal tissue complication probability. Delivery efficiency was assessed using monitor units and control points. All 3 techniques achieved comparable target coverage with no significant differences in dose distribution (P > .05). The 10XFF plan tended to reduce scalp doses (mean Dmax = 31.18 ± 5.4 Gy; Dmean = 15.30 ± 1.23 Gy) compared to 6XFF and 6XFFF, though the differences were not statistically significant (P > .05). Normal tissue complication probability for the hippocampus and tumor control probability for targets were similar across techniques. Delivery efficiency was superior for flattened beams, with the 10XFF plan requiring significantly fewer monitor units (1277.81 ± 178.87) and control points (367.40 ± 19.53) than the 6XFFF plan (P < .001). All 3 techniques provided clinically acceptable target coverage while effectively sparing the hippocampus and scalp. The 10 MV flattened photon beam showed a trend toward reduced scalp irradiation and improved delivery efficiency, suggesting its potential utility when scalp preservation or workflow efficiency is prioritized. Further prospective studies are warranted to validate these findings.
Authors
- Minzhi Zhong
- Z Chen
- Huaqu Zeng (ORCID: https://orcid.org/0009-0007-4671-7161)
- 央幸 林
- Shukui Tang
- Ming Chen (ORCID: https://orcid.org/0000-0001-5041-9342)
- Zunbei Wen
- Zhen Li
- Yuanyuan Chen
- Qifu Lin
Institutions
- Zhongshan People's Hospital (CN)
- Sun Yat-sen University Cancer Center (CN)
- Gaozhou People's Hospital (CN)
Publication Details
- Journal
- Medicine
- Published
- 2026-11-20
- DOI
- https://doi.org/10.1097/md.0000000000051600
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00