Effects of temperature and pH on early degradation of anion exchange membranes

The degradation of anion exchange membranes (AEMs) remains a major limitation to the broader deployment of membrane-based electrochemical devices. Although the operating conditions known to promote membrane deterioration are broadly recognized, the specific operating regimes and timescales that initiate degradation have not been resolved. This uncertainty hinders the definition of operational windows that are required to achieve stable and efficient membrane utilization. This work examines two degradation protocols representative of electrodialysis operating environments: thermal exposure and alkaline exposure, investigated both independently and in combination. In contrast to prior studies centered on extended operation (>2 years), the present analysis targets short exposure intervals (≤1, 24, and 48 h). The impact of these conditions was quantified through measurements of ionic conductivity, ion exchange capacity, electron microscopy, and spectroscopic analyses. Both temperature and alkaline exposure result in a continuous decrease in membrane conductivity through distinct electrochemical responses. Alkaline conditions decrease conductivity and shift the phase angle in Bode analysis toward values approaching zero, consistent with predominantly resistive behavior. In contrast, thermal exposure decreases conductivity while maintaining a nearly constant phase angle, indicating retention of capacitive contributions. These observations indicate that alkaline conditions induce a decrease in the magnitude of double-layer and diffusion boundary layer capacitances, reflected in the shift of the phase angle toward resistive behavior. When combined, elevated pH exerts a greater influence on degradation than temperature alone. Time-resolved measurements revealed a continuous, approximately linear increase in resistivity within the first hour, demonstrating that degradation initiates immediately upon exposure. Scanning electron microscopy (SEM) reveals surface morphological deterioration, while infrared spectroscopy indicates chemical transformation of functional groups. These findings demonstrate that degradation processes are activated at early operational stages, requiring precise control of initial operating conditions in electrodialysis systems to limit performance decay.

Authors

Institutions

Publication Details

Journal
International Journal of Chemical Reactor Engineering
Published
2026-11-23
DOI
https://doi.org/10.1515/ijcre-2026-0072
Primary Topic
Membrane-based Ion Separation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effects of temperature and pH on early degradation of anion exchange membranes

Guadalupe Ramos‐Sánchez, Carlos O. Castillo-Araiza, José S. Mendoza-Figueroa, Rosendo Rojas-Barragán
2 links
International Journal of Chemical Reactor Engineering
Membrane-based Ion Separation Techniques
article

Effects of temperature and pH on early degradation of anion exchange membranes

Guadalupe Ramos‐Sánchez, Carlos O. Castillo-Araiza, José S. Mendoza-Figueroa, Rosendo Rojas-Barragán
article en

Abstract

The degradation of anion exchange membranes (AEMs) remains a major limitation to the broader deployment of membrane-based electrochemical devices. Although the operating conditions known to promote membrane deterioration are broadly recognized, the specific operating regimes and timescales that initiate degradation have not been resolved. This uncertainty hinders the definition of operational windows that are required to achieve stable and efficient membrane utilization. This work examines two degradation protocols representative of electrodialysis operating environments: thermal exposure and alkaline exposure, investigated both independently and in combination. In contrast to prior studies centered on extended operation (>2 years), the present analysis targets short exposure intervals (≤1, 24, and 48 h). The impact of these conditions was quantified through measurements of ionic conductivity, ion exchange capacity, electron microscopy, and spectroscopic analyses. Both temperature and alkaline exposure result in a continuous decrease in membrane conductivity through distinct electrochemical responses. Alkaline conditions decrease conductivity and shift the phase angle in Bode analysis toward values approaching zero, consistent with predominantly resistive behavior. In contrast, thermal exposure decreases conductivity while maintaining a nearly constant phase angle, indicating retention of capacitive contributions. These observations indicate that alkaline conditions induce a decrease in the magnitude of double-layer and diffusion boundary layer capacitances, reflected in the shift of the phase angle toward resistive behavior. When combined, elevated pH exerts a greater influence on degradation than temperature alone. Time-resolved measurements revealed a continuous, approximately linear increase in resistivity within the first hour, demonstrating that degradation initiates immediately upon exposure. Scanning electron microscopy (SEM) reveals surface morphological deterioration, while infrared spectroscopy indicates chemical transformation of functional groups. These findings demonstrate that degradation processes are activated at early operational stages, requiring precise control of initial operating conditions in electrodialysis systems to limit performance decay.

International Journal of Chemical Reactor Engineering
Universidad Autónoma Metropolitana (MX), Secretaría de Ciencia, Humanidades, Tecnología e Innovación (MX), Instituto Politécnico Nacional (MX)
Membrane-based Ion Separation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon