Surface Vibration near Twin Metro Tunnels in Layered Ground: Peak Amplification and Spatial Redistribution

This study examines how an unloaded neighbouring metro tunnel modifies surface vibration in layered ground using a symmetry-reduced two-and-a-half-dimensional finite element–method of fundamental solutions–direct stiffness method (2.5D FEM–MFS–DSM) model. The formulation is assessed against an independent semi-analytical benchmark and Beijing Metro Line 10 measurements, with a mean absolute error of 1.45 dB at three surface receivers. Under coupled train excitation, the neighbouring tunnel increases the maximum Z-vibration level by 1.85 dB in the baseline configuration. At a tunnel centre depth of 24.2 m, increasing the spacing from 12 to 15 m leaves the maximum-level increment near 1.73 dB, while shifting the peak by 4 m and narrowing the 1 dB high-response region from 8.0 to 6.5 m. Complex-field analysis under a common 80 Hz moving unit load shows how the modification magnitude, relative phase, and original response level govern local changes and the surface maximum. At the baseline depth, among the three spacings examined in detail (12, 15, and 18 m), the largest maximum-response increment occurs at 15 m under the unit load but at 12 m under coupled train excitation. The results support assessing both peak magnitude and spatial redistribution when characterising ground vibration input to nearby buildings.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-19
DOI
https://doi.org/10.3390/buildings16224626
Primary Topic
Railway Engineering and Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Surface Vibration near Twin Metro Tunnels in Layered Ground: Peak Amplification and Spatial Redistribution

Chunhui Wang, Tailong Hu, Kai Sun
Buildings
Railway Engineering and Dynamics
article

Surface Vibration near Twin Metro Tunnels in Layered Ground: Peak Amplification and Spatial Redistribution

Chunhui Wang, Tailong Hu, Kai Sun
article en

Abstract

This study examines how an unloaded neighbouring metro tunnel modifies surface vibration in layered ground using a symmetry-reduced two-and-a-half-dimensional finite element–method of fundamental solutions–direct stiffness method (2.5D FEM–MFS–DSM) model. The formulation is assessed against an independent semi-analytical benchmark and Beijing Metro Line 10 measurements, with a mean absolute error of 1.45 dB at three surface receivers. Under coupled train excitation, the neighbouring tunnel increases the maximum Z-vibration level by 1.85 dB in the baseline configuration. At a tunnel centre depth of 24.2 m, increasing the spacing from 12 to 15 m leaves the maximum-level increment near 1.73 dB, while shifting the peak by 4 m and narrowing the 1 dB high-response region from 8.0 to 6.5 m. Complex-field analysis under a common 80 Hz moving unit load shows how the modification magnitude, relative phase, and original response level govern local changes and the surface maximum. At the baseline depth, among the three spacings examined in detail (12, 15, and 18 m), the largest maximum-response increment occurs at 15 m under the unit load but at 12 m under coupled train excitation. The results support assessing both peak magnitude and spatial redistribution when characterising ground vibration input to nearby buildings.

BuildingsVol. 16(22)
Qingdao Harbour Vocational & Technical College (CN), Shandong Jianzhu University (CN)
Railway Engineering and Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon