Effect of moisture-buffering wall finish materials on air-conditioning loads of museum storage: A full-scale experimental case study in Seoul

This study quantitatively investigates the effects of wall finish material on hygroscopic inertia and Precision Climate Control System (PCCS) air-conditioning loads in museum storage through full-scale experiments under Seoul's humid continental climate with dry winters. Paulownia Wood Board (PWB) and Humidity Regulating Panel (HRP) were compared. This study directly compares the hygrothermal performance of full-scale storage rooms under both excessively high and low initial humidity, with air-conditioning loads calculated from temperature, humidity ratio, and enthalpy. HRP's higher moisture buffering capacity substantially slowed indoor humidity transitions relative to PWB (5988 vs. 426 min from 80% to 70% RH; 3952 vs. 195 min from 30% to 50% RH). HRP-finished storage remained largely decoupled from outdoor humidity fluctuations, with lower Pearson correlation coefficients (−0.3691 to 0.4002 vs. 0.5094 to 0.6213 for PWB) and lower slope coefficients from Newey–West HAC regression (β 1 : −0.2377 to 0.1790 vs. 0.3650 to 0.3875 for PWB), indicating tighter synchronization of PWB with outdoor humidity. This buffering produced condition-dependent loads: under high initial humidity, HRP-finished storage incurred 33% higher cooling and 89% higher dehumidification loads than PWB, whereas under low initial humidity its loads were 22% and 54% lower, respectively. The same trends persisted when outdoor sensible heat was isolated under steady-state, infiltration-free conditions. Thus, the effect of HRP's hygroscopic inertia on air-conditioning load depends on the initial humidity state and the direction of the disturbance relative to the PCCS setpoint. Nevertheless, HRP consistently sustained the conditioned indoor state within the target dead band for longer, which can reduce the frequency of duty-cycle activation and mitigate abrupt PCCS load spikes.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-11-19
DOI
https://doi.org/10.1016/j.csite.2026.108743
Primary Topic
Hygrothermal properties of building materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effect of moisture-buffering wall finish materials on air-conditioning loads of museum storage: A full-scale experimental case study in Seoul

Sean Hay Kim, Hyunsuk Kim, Inkuk Choi
Case Studies in Thermal Engineering
Hygrothermal properties of building materials
article

Effect of moisture-buffering wall finish materials on air-conditioning loads of museum storage: A full-scale experimental case study in Seoul

Sean Hay Kim, Hyunsuk Kim, Inkuk Choi
article en

Abstract

This study quantitatively investigates the effects of wall finish material on hygroscopic inertia and Precision Climate Control System (PCCS) air-conditioning loads in museum storage through full-scale experiments under Seoul's humid continental climate with dry winters. Paulownia Wood Board (PWB) and Humidity Regulating Panel (HRP) were compared. This study directly compares the hygrothermal performance of full-scale storage rooms under both excessively high and low initial humidity, with air-conditioning loads calculated from temperature, humidity ratio, and enthalpy. HRP's higher moisture buffering capacity substantially slowed indoor humidity transitions relative to PWB (5988 vs. 426 min from 80% to 70% RH; 3952 vs. 195 min from 30% to 50% RH). HRP-finished storage remained largely decoupled from outdoor humidity fluctuations, with lower Pearson correlation coefficients (−0.3691 to 0.4002 vs. 0.5094 to 0.6213 for PWB) and lower slope coefficients from Newey–West HAC regression (β 1 : −0.2377 to 0.1790 vs. 0.3650 to 0.3875 for PWB), indicating tighter synchronization of PWB with outdoor humidity. This buffering produced condition-dependent loads: under high initial humidity, HRP-finished storage incurred 33% higher cooling and 89% higher dehumidification loads than PWB, whereas under low initial humidity its loads were 22% and 54% lower, respectively. The same trends persisted when outdoor sensible heat was isolated under steady-state, infiltration-free conditions. Thus, the effect of HRP's hygroscopic inertia on air-conditioning load depends on the initial humidity state and the direction of the disturbance relative to the PCCS setpoint. Nevertheless, HRP consistently sustained the conditioned indoor state within the target dead band for longer, which can reduce the frequency of duty-cycle activation and mitigate abrupt PCCS load spikes.

Case Studies in Thermal EngineeringVol. 88
Seoul National University of Science and Technology (KR), Texas Department of Transportation (US), Korea Military Academy (KR)
Hygrothermal properties of building materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon