Change in Discomfort Humidity in Jerusalem 1940-2025

This work analyzes the relationship between temperature and humidity during periods of thermal discomfort. Using hourly meteorological data from Jerusalem (1940–2025), it isolates hours when the Heat Index (HI) exceeds the "Comfort Heat Index" (CHI = 26.6°C / 79.9°F) defined as the threshold below which active cooling is unnecessary. For these discomfort hours, annual averages for discomfort air temperature (DCTa) and discomfort relative humidity (DCRH) were calculated and modeled using parabolic trendlines and 31-year moving averages. While air temperature (Ta) is widely simulated in climate projections, forecasting relative humidity (RH) remains highly challenging. To resolve this, this work proposes new metrics and parameters: o Discomfort Humidity Response (DHR) o Absolute Discomfort Humidity Increase (ADCHI) o Discomfort Temperature Elevation (DTE) The Discomfort Humidity Response (DHR) quantifies the hourly rate of change in humidity relative to temperature increases during discomfort periods. The observed annual change in Discomfort Humidity (DCRH) may differ from the change calculated using Discomfort Humidity Response (DHR) and the corresponding change in Discomfort Air Temperature (DCTa). To quantify this difference, a new metric, Absolute Discomfort Humidity Increase (ADCHI), is proposed. ADCHI is defined as the difference between the actual change in annual average DCRH and the change calculated using DHR. ADCHI may provide an additional indicator for climate change research. Further investigation is required to determine the factors responsible for this difference and to evaluate its potential as a climate change metric. The additional parameter introduced in this work is “Discomfort Temperature Elevation” (DTE), which is the difference between the annual average air temperature during discomfort hours (DCTa) and the annual average air temperature during all hours of the year (Ta). DTE may be further used for Discomfort Humidity (DCRH) forecast.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-19
DOI
https://doi.org/10.5281/zenodo.24363804
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Change in Discomfort Humidity in Jerusalem 1940-2025

Joseph Nowarski
Zenodo (CERN European Organization for Nuclear Research)
Urban Heat Island Mitigation
article

Change in Discomfort Humidity in Jerusalem 1940-2025

Joseph Nowarski
article en

Abstract

This work analyzes the relationship between temperature and humidity during periods of thermal discomfort. Using hourly meteorological data from Jerusalem (1940–2025), it isolates hours when the Heat Index (HI) exceeds the "Comfort Heat Index" (CHI = 26.6°C / 79.9°F) defined as the threshold below which active cooling is unnecessary. For these discomfort hours, annual averages for discomfort air temperature (DCTa) and discomfort relative humidity (DCRH) were calculated and modeled using parabolic trendlines and 31-year moving averages. While air temperature (Ta) is widely simulated in climate projections, forecasting relative humidity (RH) remains highly challenging. To resolve this, this work proposes new metrics and parameters: o Discomfort Humidity Response (DHR) o Absolute Discomfort Humidity Increase (ADCHI) o Discomfort Temperature Elevation (DTE) The Discomfort Humidity Response (DHR) quantifies the hourly rate of change in humidity relative to temperature increases during discomfort periods. The observed annual change in Discomfort Humidity (DCRH) may differ from the change calculated using Discomfort Humidity Response (DHR) and the corresponding change in Discomfort Air Temperature (DCTa). To quantify this difference, a new metric, Absolute Discomfort Humidity Increase (ADCHI), is proposed. ADCHI is defined as the difference between the actual change in annual average DCRH and the change calculated using DHR. ADCHI may provide an additional indicator for climate change research. Further investigation is required to determine the factors responsible for this difference and to evaluate its potential as a climate change metric. The additional parameter introduced in this work is “Discomfort Temperature Elevation” (DTE), which is the difference between the annual average air temperature during discomfort hours (DCTa) and the annual average air temperature during all hours of the year (Ta). DTE may be further used for Discomfort Humidity (DCRH) forecast.

Zenodo (CERN European Organization for Nuclear Research)
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon