Quality Assurance of Brachytherapy Treatment Planning Based on Template, Classification, and Segmentation Methods
Background and purpose Accurate applicator reconstruction is essential for dose calculation in CT-based brachytherapy. Reconstruction errors—driven by limited CT slice thickness and metal artifacts—can produce clinically relevant dose deviations. We developed a fully automated quality assurance (QA) pipeline that combines deep learning classification and segmentation with high-resolution template registration to verify the geometric accuracy of planned source dwell positions. Materials and methods We retrospectively collected 3,702 treatment plans from 742 gynecological cancer patients. A lightweight 3D convolutional neural network classified applicators into five categories, and an nnU-Net (v2) model segmented the three channels of Fletcher applicators. High-resolution (0.6-mm) template centerlines were registered to 3-mm clinical CT images using a progressive weighted arc-segment Kabsch algorithm. Geometric consistency was quantified with point-to-curve Euclidean distances. Error-detection performance was assessed in a simulation study in which one randomly selected dwell position per plan was displaced by 1, 3, or 5 mm (50 plans per magnitude), with 50 error-free plans as controls. Results The classification model achieved 99.28% accuracy and a weighted F1 score of 0.99. The segmentation model yielded a mean Dice coefficient of 90.7% and a 95% Hausdorff distance of approximately 1 mm. Mean distances between auto-segmented centerlines and the registered template curve ranged from 0.39 to 0.70 mm; mean dwell-point-to-template distances were 0.34–0.51 mm. In the simulation study, specificity was 94.0%; sensitivity was 36.0% for 1-mm displacements and 100% for both 3-mm and 5-mm displacements. Conclusion The proposed pipeline enables automated, high-precision QA of brachytherapy dwell positions and reliably detects displacements of 3 mm or larger, providing an objective tool for clinical treatment-plan verification that mitigates thick-slice artifacts through high-resolution template registration.
Authors
- Wenjun Tan (ORCID: https://orcid.org/0000-0002-3840-9528)
- Dazhe Zhao (ORCID: https://orcid.org/0000-0002-1377-166X)
- Tianlong Ji (ORCID: https://orcid.org/0000-0002-6551-1632)
Institutions
- Northeastern University (US)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-19
- DOI
- https://doi.org/10.21203/rs.3.rs-10916871/v1
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- preprint