Optical readout of MicroPattern Gaseous Detectors with SiPMs

Scintillation light readout of MicroPattern Gaseous Detectors (MPGDs) is used for imaging and track reconstruction applications including in optical Time Projection Chambers (TPC). Typically, high resolution CCD or CMOS imaging sensors are used and PMTs can be employed to obtain auxiliary timing information. We report on the optical readout of MPGDs with Silicon Photomultipliers (SiPMs) which enables limited spatial resolution. Arrays of SiPMs were used to read out Gaseous Electron Multipliers (GEMs) and Glass Micromegas amplification stages. Center of gravity reconstruction of hit positions yields a spatial resolution of approximately 1.35 mm for signals shared across multiple SiPMs. High gain of the amplification stage as well as the SiPMs enables good signal sharing and is advantageous for position reconstruction.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-18
DOI
https://doi.org/10.48550/arxiv.2611.24660
Primary Topic
Particle Detector Development and Performance
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Optical readout of MicroPattern Gaseous Detectors with SiPMs

D. Janssens, L. Ropelewski, Rob Veenhof, E. Oliveri et al.
arXiv (Cornell University)
Particle Detector Development and Performance
preprint

Optical readout of MicroPattern Gaseous Detectors with SiPMs

D. Janssens, L. Ropelewski, Rob Veenhof, E. Oliveri, M. van Stenis, M. Lisowska, E. Jelinkova, F. Garcia, E. Pollacco, K. J. Flöthner, B. Schönfelder, H. Müller, L. Scharenberg, F. M. Brunbauer, E. Tuovinen, D. Marques
preprint en

Abstract

Scintillation light readout of MicroPattern Gaseous Detectors (MPGDs) is used for imaging and track reconstruction applications including in optical Time Projection Chambers (TPC). Typically, high resolution CCD or CMOS imaging sensors are used and PMTs can be employed to obtain auxiliary timing information. We report on the optical readout of MPGDs with Silicon Photomultipliers (SiPMs) which enables limited spatial resolution. Arrays of SiPMs were used to read out Gaseous Electron Multipliers (GEMs) and Glass Micromegas amplification stages. Center of gravity reconstruction of hit positions yields a spatial resolution of approximately 1.35 mm for signals shared across multiple SiPMs. High gain of the amplification stage as well as the SiPMs enables good signal sharing and is advantageous for position reconstruction.

arXiv (Cornell University)
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon