Homogeneous liquid–liquid microextraction using low-density solvents for BHA and BHT extraction from artificial tears followed by GC–FID
An efficient homogeneous liquid–liquid microextraction approach was established for the extraction of butylated hydroxy anisole and butylated hydroxy toluene from artificial tear samples prior to gas chromatography–flame ionization detection. The proposed approach was designed to combine high analytical performance with procedural simplicity, short extraction time, and minimal organic solvent consumption. In the extraction procedure, a few µL of toluene was first added to the aqueous solution of the analytes to form a homogeneous solution. Subsequently, a few µL of di- n -butyl ether was introduced as a phase-separating solvent, resulting in the formation of a turbid system. After centrifugation, the low-density organic phase containing the enriched analytes was accumulated in the capillary section of a specially home-made glass extraction tube, allowing convenient removing and injection into the separation system. The influences of critical experimental parameters, such as type and volume of extraction solvents, vortexing time, centrifugation conditions, and pH were systematically investigated and optimized to achieve maximum extraction efficiency. Under the optimized conditions, enrichment factors of 2454 and 1607 were obtained for butylated hydroxytoluene and butylated hydroxy anisole, respectively. The method presented satisfactory linearity over the concentration range of 10–5000 µg L −1 , with coefficients of determination higher than 0.99. The limits of detection were 0.70 µg L −1 for butylated hydroxytoluene and 2.3 µg L −1 for butylated hydroxy anisole while the intra- and inter-day relative standard deviations were below 10%. Also, extraction recoveries were 65% for butylated hydroxy anisole and 98% for butylated hydroxytoluene. Key advantages of this approach included simplicity, rapidity, cost-effectiveness, reliability, and high enrichment factors. The proposed method provided a rapid and economical approach for the determination of phenolic antioxidants in ophthalmic formulations.
Authors
- Mir Ali Farajzadeh (ORCID: https://orcid.org/0000-0003-3746-0011)
- Sanaz Barazandeh
- Mahsa Ghoreishizadeh
- Mohammd Reza Afshar Mogaddam
Institutions
- Khazar University (AZ)
- Tabriz University of Medical Sciences (IR)
- University of Tabriz (IR)
- Near East University (CY)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-19
- DOI
- https://doi.org/10.1038/s41598-026-68962-0
- Primary Topic
- Analytical chemistry methods development
- Type
- article
- Field-Weighted Citation Impact
- 0.00