CSET-3D for Component-Level Thermal Attribution on Stereo-Reconstructed Power Equipment Surfaces

Thermal observations may be consistent with several adjacent components of power equipment. CSET-3D associates them with a component-labeled exterior surface reconstructed from an RGB stereo pair. The thermal transport plan uses projection and visibility costs and an unresolved destination. Admission and support rules determine which observations contribute to component descriptors. A separate acoustic plan provides exploratory direction-to-surface association. All quantitative results are based on a computational reference scene model with reference-derived disparity, component masks, and 3D–2D correspondences. The learned stereo, segmentation, and XoFTR front ends are outside the quantitative evaluation. The Foshan field demonstration is qualitative. The primary evaluation comprises 500 cases. In the 100 nominal cases, CSET-3D has lower integrated thermal attribution error over common attainable coverage than the residual-ranked nearest-hard and point-cloud comparators, with lower default correct yield and retention. Acoustic correct yield is lower than for both comparators. The findings characterize the trade-off between thermal attribution error and evidence retention on the modeled exterior surface.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-19
DOI
https://doi.org/10.3390/en19225595
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

CSET-3D for Component-Level Thermal Attribution on Stereo-Reconstructed Power Equipment Surfaces

Hui Rong Xiao, Tianrui Yin, Weiguan Wang, Jiahua Guan et al.
Energies
Thermography and Photoacoustic Techniques
article

CSET-3D for Component-Level Thermal Attribution on Stereo-Reconstructed Power Equipment Surfaces

Hui Rong Xiao, Tianrui Yin, Weiguan Wang, Jiahua Guan, Zhongbiao Ling, Feng Hu, Xin Li
article en

Abstract

Thermal observations may be consistent with several adjacent components of power equipment. CSET-3D associates them with a component-labeled exterior surface reconstructed from an RGB stereo pair. The thermal transport plan uses projection and visibility costs and an unresolved destination. Admission and support rules determine which observations contribute to component descriptors. A separate acoustic plan provides exploratory direction-to-surface association. All quantitative results are based on a computational reference scene model with reference-derived disparity, component masks, and 3D–2D correspondences. The learned stereo, segmentation, and XoFTR front ends are outside the quantitative evaluation. The Foshan field demonstration is qualitative. The primary evaluation comprises 500 cases. In the 100 nominal cases, CSET-3D has lower integrated thermal attribution error over common attainable coverage than the residual-ranked nearest-hard and point-cloud comparators, with lower default correct yield and retention. Acoustic correct yield is lower than for both comparators. The findings characterize the trade-off between thermal attribution error and evidence retention on the modeled exterior surface.

EnergiesVol. 19(22)
Wuhan University (CN), Power Grid Corporation (India) (IN)
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.