Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging
Objectives To evaluate diagnostic performance, radiation dose, and quantitative spectral characteristics of dual-phase photon-counting CT (PCD-CT) for parathyroid adenoma localization after inconclusive first-line imaging. Materials and methods Consecutive patients with primary hyperparathyroidism and negative, discordant, or inconclusive first-line imaging underwent paired [ 18 F]FECh PET/CT and dual-phase PCD-CT with arterial and venous acquisitions. Three radiologists, blinded to clinical and reference-standard information, retrospectively assessed arterial and portal-venous 40- and 70-keV images and VNC reconstructions. The reference standard comprised surgery/histopathology with biochemical confirmation, concordant PET/CT with persistent biochemical disease in nonsurgical positive patients, or clinical/biochemical resolution in negative patients. Lesion-level sensitivity, positive predictive value (PPV), and interreader intraclass correlation (ICC) were calculated. Aorta-normalized attenuation and wash-in and wash-out metrics were compared among adenomas, thyroid tissue, and lymph nodes. Results Forty-nine patients (mean age, 64.2 ± 10.9 years; 42 women) were included, with 45 patients having 49 reference-standard-positive lesions. PCD-CT lesion-level sensitivity was 67.3%–83.7%, and PPV 67.3%–90.0%, with an interreader agreement of 0.506. Aorta-adjusted wash-out was greater in adenomas (27.2%) than in thyroid (20.2%) and lymph nodes (−3.1%; both p < 0.001). Arterial adenoma–thyroid attenuation and wash-in overlapped between adenomas did not differ significantly (arterial p = 0.615 and thyroid tissue. 0.945 at 40 and 70 keV; wash-in p = 0.363). Mean estimated effective dose was 1.23 ± 0.47 mSv. Conclusion Dual-phase PCD-CT provided reader-dependent parathyroid localization at low radiation dose in a difficult second-line cohort. Quantitative wash-out may aid differentiation from thyroid and lymph-node mimics but requires prospective threshold validation. Key Points Question Inconclusive first-line imaging complicates parathyroid lesion localization. Findings Reader sensitivity ranged from 67.3% to 83.7% at 1.23 mSv. Critical relevance statement Aorta-adjusted wash-out differed among parathyroid lesions, thyroid tissue, and lymph nodes.
Authors
- Jakob Weiß (ORCID: https://orcid.org/0000-0002-3879-0568)
- Thomas Stein (ORCID: https://orcid.org/0009-0002-3277-269X)
- Fabian Bamberg (ORCID: https://orcid.org/0000-0002-7460-3942)
- Philipp Tobias Meyer (ORCID: https://orcid.org/0000-0001-8336-750X)
- Felix Kind (ORCID: https://orcid.org/0000-0002-9398-5747)
- Maximilian Frederik Russe (ORCID: https://orcid.org/0000-0003-3187-2429)
- Marco Reisert (ORCID: https://orcid.org/0000-0003-2742-1940)
- Anna Maria Fink (ORCID: https://orcid.org/0009-0002-9903-283X)
- Alexander Rau (ORCID: https://orcid.org/0000-0001-5881-6043)
- Christian Goetz (ORCID: https://orcid.org/0000-0001-9524-0813)
- Prerana Agarwal (ORCID: https://orcid.org/0000-0002-6784-6727)
- Stephan Rau (ORCID: https://orcid.org/0000-0002-8992-2401)
- Carl Philipp Simon
- Johannes Benjamin Jahn
Institutions
- University of Freiburg (DE)
- University Medical Center Freiburg (DE)
Publication Details
- Journal
- Insights into Imaging
- Published
- 2026-11-19
- DOI
- https://doi.org/10.1186/s13244-026-02482-3
- Primary Topic
- Thyroid and Parathyroid Surgery
- Type
- article
- Field-Weighted Citation Impact
- 0.00