Enhancing adsorption refrigeration system efficiency via mass recovery: Experimental insights

This study experimentally investigates a two-bed adsorption refrigeration system using activated carbon–methanol as the adsorbent–refrigerant pair, with emphasis on the effect of mass recovery on cycle performance. Mass recovery utilizes the pressure difference between the desorbing and adsorbing beds by transferring high-pressure methanol vapor from the desorbing bed to the cooler adsorbing bed during the bed switching period. Experiments were conducted without mass recovery and with mass-recovery durations of 155, 180, and 205 s. The results show that a mass-recovery duration of 180 s provides the optimum cycle performance. The COP increased from 0.102 without mass recovery to 0.116 with 180 s of mass recovery, corresponding to an improvement of 13.72%. The results demonstrate that appropriate selection of mass-recovery duration can enhance the performance of a two-bed adsorption refrigeration system while utilizing the pressure differential between the beds during the switching process.

Authors

Institutions

Publication Details

Journal
Next Chemical Engineering
Published
2026-11-19
DOI
https://doi.org/10.1016/j.nxcen.2026.100125
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Enhancing adsorption refrigeration system efficiency via mass recovery: Experimental insights

Gulshan Sachdeva, Ashok Verma
Next Chemical Engineering
Adsorption and Cooling Systems
article

Enhancing adsorption refrigeration system efficiency via mass recovery: Experimental insights

Gulshan Sachdeva, Ashok Verma
article en

Abstract

This study experimentally investigates a two-bed adsorption refrigeration system using activated carbon–methanol as the adsorbent–refrigerant pair, with emphasis on the effect of mass recovery on cycle performance. Mass recovery utilizes the pressure difference between the desorbing and adsorbing beds by transferring high-pressure methanol vapor from the desorbing bed to the cooler adsorbing bed during the bed switching period. Experiments were conducted without mass recovery and with mass-recovery durations of 155, 180, and 205 s. The results show that a mass-recovery duration of 180 s provides the optimum cycle performance. The COP increased from 0.102 without mass recovery to 0.116 with 180 s of mass recovery, corresponding to an improvement of 13.72%. The results demonstrate that appropriate selection of mass-recovery duration can enhance the performance of a two-bed adsorption refrigeration system while utilizing the pressure differential between the beds during the switching process.

Next Chemical EngineeringVol. 3
National Institute of Technology Kurukshetra (IN)
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon