Association of uterine‐entry technique with chorioamniotic membrane separation after fetoscopic laser surgery for twin‐to‐twin transfusion syndrome: two‐center retrospective cohort study

OBJECTIVE: Chorioamniotic membrane separation (CAS) is a recognized iatrogenic complication of fetoscopic laser photocoagulation (FLP), the standard treatment for twin-to-twin transfusion syndrome (TTTS). We compared the incidence of CAS between two different means of uterine entry for FLP: the sharp-trocar and Seldinger techniques. METHODS: This was a retrospective cohort study of monochorionic diamniotic twin pregnancies complicated by TTTS undergoing FLP between 16 + 0 and 26 + 0 weeks' gestation at two tertiary fetal centers in the USA from January 2012 to August 2025. The uterine-entry technique was center-specific: one center used the Seldinger technique exclusively, while the other used sharp-trocar entry exclusively. All patients at both centers underwent routine short-interval postoperative fetal ultrasound examination, with particular attention paid to membrane integrity at the entry sites. The primary outcome was CAS diagnosed intraoperatively or during postoperative ultrasound performed within 48 h after surgery. Secondary outcomes included gestational age at delivery, latency from FLP to delivery, preterm birth < 32 and < 34 weeks, and survival 48 h after FLP, at birth and at 30 days postnatally. Univariable and multivariable logistic regression analysis evaluated associations between clinically relevant anatomical and procedural variables and the occurrence of CAS. RESULTS: In total, 889 pregnancies that underwent a FLP procedure for TTTS were included (591 using Seldinger entry, 298 using sharp-trocar entry). Sharp-trocar entry was associated with a lower rate of CAS (8.1% vs 14.4%; P = 0.01) and lower rates of delivery before 32 weeks (42% vs 59%; P < 0.001) and delivery before 34 weeks (61% vs 77%; P < 0.001). Among cases with complete data, after adjusting for clinically relevant anatomical and procedural variables, sharp-trocar entry was independently associated with lower odds of CAS (adjusted odds ratio, 0.46 (95% CI, 0.24-0.82); P = 0.01). Delivery was later in the sharp-trocar entry group (median gestational age, 32 + 4 (interquartile range (IQR), 29 + 1 to 34 + 4) weeks vs 31 + 0 (IQR, 28 + 1 to 33 + 5) weeks; P < 0.001), and the median interval from procedure to delivery was longer (82 (IQR, 58-105) days vs 74 (IQR, 48-96) days; P = 0.002). Survival of donor and recipient twins 48 h after FLP, at birth and at 30 days postnatally, was similar between the two groups. CONCLUSIONS: Sharp-trocar entry during FLP for TTTS was associated with a lower incidence of CAS, longer latency from procedure to delivery and later gestational age at delivery compared with the Seldinger technique. Because the entry technique was center-specific, these differences cannot be attributed exclusively to the technique. Survival was similar between the two groups. Prospective studies in which both entry techniques are used in the same center are needed to confirm these findings. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.

Authors

Institutions

Publication Details

Journal
Ultrasound in Obstetrics and Gynecology
Published
2026-11-18
DOI
https://doi.org/10.1002/uog.70374
Primary Topic
Assisted Reproductive Technology and Twin Pregnancy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Association of uterine‐entry technique with chorioamniotic membrane separation after fetoscopic laser surgery for twin‐to‐twin transfusion syndrome: two‐center retrospective cohort study

Brian Burnett, Roopali Donepudi, Ahmed Abobakr Nassr, Jessian Louis Munoz et al.
Ultrasound in Obstetrics and Gynecology
Assisted Reproductive Technology and Twin Pregnancy
article

Association of uterine‐entry technique with chorioamniotic membrane separation after fetoscopic laser surgery for twin‐to‐twin transfusion syndrome: two‐center retrospective cohort study

Brian Burnett, Roopali Donepudi, Ahmed Abobakr Nassr, Jessian Louis Munoz, Ozhan Mehmet Turan, Cara M. Buskmiller, Rebecca Johnson, Michael Anthony Belfort, C. M. Parobek, M. M. Gil, M. Imamoglu, M. S. Cortes
article en

Abstract

OBJECTIVE: Chorioamniotic membrane separation (CAS) is a recognized iatrogenic complication of fetoscopic laser photocoagulation (FLP), the standard treatment for twin-to-twin transfusion syndrome (TTTS). We compared the incidence of CAS between two different means of uterine entry for FLP: the sharp-trocar and Seldinger techniques. METHODS: This was a retrospective cohort study of monochorionic diamniotic twin pregnancies complicated by TTTS undergoing FLP between 16 + 0 and 26 + 0 weeks' gestation at two tertiary fetal centers in the USA from January 2012 to August 2025. The uterine-entry technique was center-specific: one center used the Seldinger technique exclusively, while the other used sharp-trocar entry exclusively. All patients at both centers underwent routine short-interval postoperative fetal ultrasound examination, with particular attention paid to membrane integrity at the entry sites. The primary outcome was CAS diagnosed intraoperatively or during postoperative ultrasound performed within 48 h after surgery. Secondary outcomes included gestational age at delivery, latency from FLP to delivery, preterm birth < 32 and < 34 weeks, and survival 48 h after FLP, at birth and at 30 days postnatally. Univariable and multivariable logistic regression analysis evaluated associations between clinically relevant anatomical and procedural variables and the occurrence of CAS. RESULTS: In total, 889 pregnancies that underwent a FLP procedure for TTTS were included (591 using Seldinger entry, 298 using sharp-trocar entry). Sharp-trocar entry was associated with a lower rate of CAS (8.1% vs 14.4%; P = 0.01) and lower rates of delivery before 32 weeks (42% vs 59%; P < 0.001) and delivery before 34 weeks (61% vs 77%; P < 0.001). Among cases with complete data, after adjusting for clinically relevant anatomical and procedural variables, sharp-trocar entry was independently associated with lower odds of CAS (adjusted odds ratio, 0.46 (95% CI, 0.24-0.82); P = 0.01). Delivery was later in the sharp-trocar entry group (median gestational age, 32 + 4 (interquartile range (IQR), 29 + 1 to 34 + 4) weeks vs 31 + 0 (IQR, 28 + 1 to 33 + 5) weeks; P < 0.001), and the median interval from procedure to delivery was longer (82 (IQR, 58-105) days vs 74 (IQR, 48-96) days; P = 0.002). Survival of donor and recipient twins 48 h after FLP, at birth and at 30 days postnatally, was similar between the two groups. CONCLUSIONS: Sharp-trocar entry during FLP for TTTS was associated with a lower incidence of CAS, longer latency from procedure to delivery and later gestational age at delivery compared with the Seldinger technique. Because the entry technique was center-specific, these differences cannot be attributed exclusively to the technique. Survival was similar between the two groups. Prospective studies in which both entry techniques are used in the same center are needed to confirm these findings. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.

Ultrasound in Obstetrics and Gynecology
University of Maryland, Baltimore (US), Baylor College of Medicine (US), Texas Children's Hospital (US)
Assisted Reproductive Technology and Twin Pregnancy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.