Echocardiographic assessment of cardiac function in patients with fontan circulation during 24-hour normobaric hypoxia

Objective The function of the Fontan circulation depends on a low pulmonary vascular resistance (PVR), which can increase under hypoxic conditions and might lead to hemodynamic deterioration. Consequently, prolonged exposure to hypoxia has traditionally been considered too risky, although data are scarce. We investigated whether 24 h of moderate normobaric hypoxia, equivalent to 2,500 masl altitude, is associated with changes in resting systemic ventricular function and mean Fontan pathway pressure (P FP ) in clinically stable, non-fenestrated Fontan patients. Methods Sixteen patients with hemodynamically stable, non-fenestrated Fontan circulation (age 16–38 years) underwent a 4-day protocol including two consecutive days of simulated normobaric hypoxia induced by nitrogen dilution. Echocardiographic assessments were performed under normoxic conditions and repeated on each day of hypoxic exposure, with simultaneous measurement of P FP via a peripherally inserted central catheter. Additionally, vital signs and NT-proBNP levels were assessed under both normoxic and hypoxic conditions. Results No significant changes were detected in the assessed systolic and diastolic echocardiographic parameters, P FP or NT-pro-BNP. Mean P FP remained stable between 11.1 and 11.9 mmHg. Peripheral oxygen saturation decreased after 12 h (86.1 ± 4.2%) and 24 h (87.2 ± 3.6%) compared with baseline (94.2 ± 3.1%; p < 0.001). Heart rate increased from 62.6 ± 13.2 bpm to 69.0 ± 14.5 bpm after 24 h of hypoxia ( p < 0.05). Diastolic blood pressure decreased after 24 h of hypoxia (75.4 ± 11.4 mmHg to 69.9 ± 9.4 mmHg; p < 0.05). Conclusion Simulated normobaric hypoxia equivalent to 2,500 masl for ≥ 24 h was not associated with significant changes in the cardiac parameters examined or in P FP in hemodynamically stable patients with non-fenestrated Fontan circulation, despite a pronounced decrease in oxygen saturation. The results provide important insights into the hemodynamic response to prolonged normobaric hypoxia and suggest that this exposure was feasible in this selected population under controlled conditions.

Authors

Institutions

Publication Details

Journal
Frontiers in Pediatrics
Published
2026-11-19
DOI
https://doi.org/10.3389/fped.2026.1987336
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Echocardiographic assessment of cardiac function in patients with fontan circulation during 24-hour normobaric hypoxia

Ulrike Herberg, Jan‐Niklas Hönemann, Jens Jordan, Tobias Kratz et al.
Frontiers in Pediatrics
Congenital Heart Disease Studies
article

Echocardiographic assessment of cardiac function in patients with fontan circulation during 24-hour normobaric hypoxia

Ulrike Herberg, Jan‐Niklas Hönemann, Jens Jordan, Tobias Kratz, Johannes Breuer, Wilhelm Bloch, Jens Tank, Marijke Grau, Nicole Müller, Julian Alexander von Hasselbach, Alena Heß
article en

Abstract

Objective The function of the Fontan circulation depends on a low pulmonary vascular resistance (PVR), which can increase under hypoxic conditions and might lead to hemodynamic deterioration. Consequently, prolonged exposure to hypoxia has traditionally been considered too risky, although data are scarce. We investigated whether 24 h of moderate normobaric hypoxia, equivalent to 2,500 masl altitude, is associated with changes in resting systemic ventricular function and mean Fontan pathway pressure (P FP ) in clinically stable, non-fenestrated Fontan patients. Methods Sixteen patients with hemodynamically stable, non-fenestrated Fontan circulation (age 16–38 years) underwent a 4-day protocol including two consecutive days of simulated normobaric hypoxia induced by nitrogen dilution. Echocardiographic assessments were performed under normoxic conditions and repeated on each day of hypoxic exposure, with simultaneous measurement of P FP via a peripherally inserted central catheter. Additionally, vital signs and NT-proBNP levels were assessed under both normoxic and hypoxic conditions. Results No significant changes were detected in the assessed systolic and diastolic echocardiographic parameters, P FP or NT-pro-BNP. Mean P FP remained stable between 11.1 and 11.9 mmHg. Peripheral oxygen saturation decreased after 12 h (86.1 ± 4.2%) and 24 h (87.2 ± 3.6%) compared with baseline (94.2 ± 3.1%; p < 0.001). Heart rate increased from 62.6 ± 13.2 bpm to 69.0 ± 14.5 bpm after 24 h of hypoxia ( p < 0.05). Diastolic blood pressure decreased after 24 h of hypoxia (75.4 ± 11.4 mmHg to 69.9 ± 9.4 mmHg; p < 0.05). Conclusion Simulated normobaric hypoxia equivalent to 2,500 masl for ≥ 24 h was not associated with significant changes in the cardiac parameters examined or in P FP in hemodynamically stable patients with non-fenestrated Fontan circulation, despite a pronounced decrease in oxygen saturation. The results provide important insights into the hemodynamic response to prolonged normobaric hypoxia and suggest that this exposure was feasible in this selected population under controlled conditions.

Frontiers in PediatricsVol. 14
German Sport University Cologne (DE), University of Cologne (DE), University Hospital Bonn (DE), Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE), University Hospital Cologne (DE), RWTH Aachen University (DE)
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon