When Safe-Region Properties Reject Correct Repairs
A property proved on a region where a faulty program is safe need not hold on legitimate behavior outside that region. We examine this limitation in a bounded C repair-assessment pipeline. In the historical final study, all 23 admitted safety-passing repair calls matched the reference. Preservation accepted all 23, whereas a template-property gate flagged 4 and a trace-derived-property gate flagged 19. Detection of incorrect repairs therefore could not be estimated. A model-free continuation reuses these repairs and development pools, yielding 35 non-manufactured repair calls across 11 families. In six families, restricting a property check to its certified region eliminated false flags in at least one fully resolved comparison for a detector. This follows from preservation when the check uses only observations that preservation covers. Original and reference programs agreed on all 24 certified small and medium family-region pairs. The selection rule therefore left no contaminated certified region on which to assess harm. The audit documents abstentions, corrections to the analysis and a deviation from the solver timeout protocol.
Authors
- S. M. Abdulla Al Mamun
Institutions
- University of Manchester (GB)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-19
- DOI
- https://doi.org/10.5281/zenodo.24374637
- Primary Topic
- Software Testing and Debugging Techniques
- Type
- preprint