Accounting for torsional coupling in the seismic assessment of URM-infilled RC buildings on sloping ground using coupled IM–EDP parameters

Un-reinforced masonry-infilled reinforced concrete buildings constructed on sloping terrain are highly vulnerable to seismic events due to geometric irregularities, torsional effects, and complex infill–frame interactions, often exacerbated by the presence of functional openings in terms of doors and windows. Despite widespread damage to such structures in past earthquakes, comprehensive studies addressing their seismic performance while accounting for these combined complexities remain limited. This study proposes a methodology for evaluating the seismic performance of hill buildings by explicitly considering (i) terrain-induced geometric irregularities, (ii) infill–frame interaction with openings in infill panels, and (iii) bidirectional coupling of seismic demand due to torsional irregularity. A suite of 50 far-field ground motion pairs was employed in bidirectional cloud analysis and incremental dynamic analysis to assess the performance of three structural configurations, viz. flatland (FL), split-foundation (SF), and step-back (SB) under both gravity load designed and special moment resisting frame design levels. Maximum drift ratio (MDR), particularly in its geometric mean form (MDR^), is identified as the most effective engineering demand parameter (EDP). Among Intensity Measures (IMs), spectral-based metrics such as S a,avg (0.2 T –3 T ) and S a ( T ) demonstrated superior correlation with EDPs compared to peak ground acceleration. Coupled parameters, expressed as geometric mean (IM^) or resultant (IM*) of orthogonal components, showed improved correlation, especially for buildings with torsional irregularities. Fragility curves revealed significant underestimation of collapse probabilities when uncoupled IMs were used in sloped configurations. Collapse in FL buildings varied with design detailing, while hill buildings predominantly exhibit shear failure in short uphill columns across the seismic design levels. The findings underscore the need for tailored assessment tools and design strategies for buildings on sloping ground in high-seismicity regions such as the Indian Himalayas.

Authors

Institutions

Publication Details

Journal
International Journal of Damage Mechanics
Published
2026-11-19
DOI
https://doi.org/10.1177/10567895261508282
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Accounting for torsional coupling in the seismic assessment of URM-infilled RC buildings on sloping ground using coupled IM–EDP parameters

Putul Haldar, Z. Naorem
International Journal of Damage Mechanics
Seismic Performance and Analysis
article

Accounting for torsional coupling in the seismic assessment of URM-infilled RC buildings on sloping ground using coupled IM–EDP parameters

Putul Haldar, Z. Naorem
article en

Abstract

Un-reinforced masonry-infilled reinforced concrete buildings constructed on sloping terrain are highly vulnerable to seismic events due to geometric irregularities, torsional effects, and complex infill–frame interactions, often exacerbated by the presence of functional openings in terms of doors and windows. Despite widespread damage to such structures in past earthquakes, comprehensive studies addressing their seismic performance while accounting for these combined complexities remain limited. This study proposes a methodology for evaluating the seismic performance of hill buildings by explicitly considering (i) terrain-induced geometric irregularities, (ii) infill–frame interaction with openings in infill panels, and (iii) bidirectional coupling of seismic demand due to torsional irregularity. A suite of 50 far-field ground motion pairs was employed in bidirectional cloud analysis and incremental dynamic analysis to assess the performance of three structural configurations, viz. flatland (FL), split-foundation (SF), and step-back (SB) under both gravity load designed and special moment resisting frame design levels. Maximum drift ratio (MDR), particularly in its geometric mean form (MDR^), is identified as the most effective engineering demand parameter (EDP). Among Intensity Measures (IMs), spectral-based metrics such as S a,avg (0.2 T –3 T ) and S a ( T ) demonstrated superior correlation with EDPs compared to peak ground acceleration. Coupled parameters, expressed as geometric mean (IM^) or resultant (IM*) of orthogonal components, showed improved correlation, especially for buildings with torsional irregularities. Fragility curves revealed significant underestimation of collapse probabilities when uncoupled IMs were used in sloped configurations. Collapse in FL buildings varied with design detailing, while hill buildings predominantly exhibit shear failure in short uphill columns across the seismic design levels. The findings underscore the need for tailored assessment tools and design strategies for buildings on sloping ground in high-seismicity regions such as the Indian Himalayas.

International Journal of Damage Mechanics
Indian Institute of Technology Ropar (IN)
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon