MIL-68(Al)-Embedded Polymer Monolith in Pipette Tips for Simultaneous Extraction of the Early- and Late-Stage Aflatoxin B1 Precursors Averantin and Sterigmatocystin from Rice
Monitoring the biosynthetic precursors of aflatoxin B1 (AFB1) may allow contamination risk in cereals to be recognized before the toxin accumulates, but their trace levels and complex matrices demand efficient sample preparation. Herein, the aluminium metal–organic framework MIL-68(Al) was embedded in a poly(ethylene glycol dimethacrylate) polymer monolith (PM) by in situ polymerization inside pipette tips (MIL-68(Al)@PM) for the simultaneous pipette-tip micro-solid-phase extraction of the early-stage precursor averantin (AVN) and the late-stage precursor sterigmatocystin (STC) in a single loading–elution step before HPLC-UV determination. A MOF-free monolith retained neither analyte, identifying MIL-68(Al) as the source of the (non-imprinted, class-selective) adsorption sites. The monolith showed a cauliflower-like, mesopore-dominated structure with uniformly distributed Al. DFT calculations indicated thermodynamically favorable adsorption of both analytes on MIL-68(Al), with a slightly stronger adsorption energy for AVN (−1.13 vs. −0.91 eV), and XPS showed no new chemical states after adsorption, consistent with non-covalent adsorption. Coupled with HPLC-UV, the method gave linear ranges of 2–200 μg/kg (AVN) and 5–200 μg/kg (STC), LODs of 0.52 and 0.97 μg/kg, and recoveries of 79.6–107.7% with RSDs ≤ 16.2%. Each extraction consumed only 80 μL of acetone, tip-to-tip RSDs were ≤3.5%, and a single tip retained ≥ 90% of its initial efficiency for six cycles. AVN and STC were not detected in 15 commercial rice samples. The method achieved a BAGI practicality score of 67.5, above the recommended value of 60, and the GAPI assessment showed that the tip-based extraction step is micro-scale and consumes only 80 μL of elution solvent. The method provides a simple, low-solvent sample preparation tool toward precursor-based early warning of aflatoxin contamination.
Authors
- Yong Tang (ORCID: https://orcid.org/0000-0002-5036-4350)
- Peng Peng (ORCID: https://orcid.org/0009-0001-8344-0356)
- Xiang Chen (ORCID: https://orcid.org/0000-0001-8187-636X)
- Qi Sun (ORCID: https://orcid.org/0000-0002-9247-2659)
- Qing Zuo
- Weiwei Liu
- Haiyu Li
- Jianmei Li
- Zongyang Zhao
Institutions
- Chongqing Normal University (CN)
- Chongqing Institute of Green and Intelligent Technology (CN)
- Chongqing College of Traditional Chinese Medicine (CN)
Publication Details
- Journal
- Molecules
- Published
- 2026-11-19
- DOI
- https://doi.org/10.3390/molecules31224211
- Primary Topic
- Analytical chemistry methods development
- Type
- article
- Field-Weighted Citation Impact
- 0.00