Chromatographic screening of essential amino acids in sports nutrition products: selection of effective eluents and detection

Purpose – to study the conditions of thin‑-layer chromatography for the qualitative and quantitative determination of essential amino acids in sports nutrition products. Methods. The work was carried out using standard solutions of essential amino acids (methionine, tryptophan, isoleucine, leucine, valine, threonine, phenylalanine, lysine, and histidine), chromatographic plates from various manufacturers (Sorbfil, Silufol UV-254, DC-Alufolien Kieselgel), a UV lamp (254 nm, China), and a drying oven (SNOL 67/350, Lithuania). Six one‑-dimensional and three two‑-dimensional eluent systems of different polarity were studied. Visualization was performed with three detecting reagents: ninhydrin, vanillin, and iodine vapour. Quantitative processing of chromatograms was carried out using ImageJ software. The accuracy of the methods was verified by the «added-found» test at a confidence level of 0.95. Results. The best separation in the one – dimensional mode was achieved with the system ethyl acetate – ethanol – ammonia (25 %) – water (6:3:0.5:0.5), where all amino acids produced clear, non‑-overlapping spots with a uniform distribution of Rf values across the plate. Among the two – dimensional systems, the most efficient was the combination of isopropanol – ammonia – water (40:2:10) in the first direction and tert – butanol – methylethylketone – ammonia – water (50:30:10:10) in the second, which allowed even the structural isomers leucine and isoleucine to be spatially resolved. The best detecting reagent, providing a contrasting violet colouration of all zones, was a 2 % solution of ninhydrin in acetone. The «Sorbfil» plates with a sorbent layer thickness of 0.20–-0.25 mm showed the highest spot brightness and reproducibility. The calculated retention factors (k′) and selectivity (α) confirmed the high efficiency of the chosen systems. Testing on real samples of a protein shake and a dry concentrate gave results that did not statistically differ from the manufacturer's declared values. Conclusion. The proposed rapid TLC procedures are suitable for routine screening of the amino acid composition of sports nutrition products and can serve as a cost – effective alternative to expensive HPLC in incoming quality control.

Authors

Institutions

Publication Details

Journal
Proceedings of the Southwest State University Series Engineering and Technologies
Published
2026-11-18
DOI
https://doi.org/10.21869/2223-1528-2026-16-3-167-181
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Chromatographic screening of essential amino acids in sports nutrition products: selection of effective eluents and detection

Olga Shashkanova, A. G. Potanina
Proceedings of the Southwest State University Series Engineering and Technologies
Analytical Chemistry and Chromatography
article

Chromatographic screening of essential amino acids in sports nutrition products: selection of effective eluents and detection

Olga Shashkanova, A. G. Potanina
article en

Abstract

Purpose – to study the conditions of thin‑-layer chromatography for the qualitative and quantitative determination of essential amino acids in sports nutrition products. Methods. The work was carried out using standard solutions of essential amino acids (methionine, tryptophan, isoleucine, leucine, valine, threonine, phenylalanine, lysine, and histidine), chromatographic plates from various manufacturers (Sorbfil, Silufol UV-254, DC-Alufolien Kieselgel), a UV lamp (254 nm, China), and a drying oven (SNOL 67/350, Lithuania). Six one‑-dimensional and three two‑-dimensional eluent systems of different polarity were studied. Visualization was performed with three detecting reagents: ninhydrin, vanillin, and iodine vapour. Quantitative processing of chromatograms was carried out using ImageJ software. The accuracy of the methods was verified by the «added-found» test at a confidence level of 0.95. Results. The best separation in the one – dimensional mode was achieved with the system ethyl acetate – ethanol – ammonia (25 %) – water (6:3:0.5:0.5), where all amino acids produced clear, non‑-overlapping spots with a uniform distribution of Rf values across the plate. Among the two – dimensional systems, the most efficient was the combination of isopropanol – ammonia – water (40:2:10) in the first direction and tert – butanol – methylethylketone – ammonia – water (50:30:10:10) in the second, which allowed even the structural isomers leucine and isoleucine to be spatially resolved. The best detecting reagent, providing a contrasting violet colouration of all zones, was a 2 % solution of ninhydrin in acetone. The «Sorbfil» plates with a sorbent layer thickness of 0.20–-0.25 mm showed the highest spot brightness and reproducibility. The calculated retention factors (k′) and selectivity (α) confirmed the high efficiency of the chosen systems. Testing on real samples of a protein shake and a dry concentrate gave results that did not statistically differ from the manufacturer's declared values. Conclusion. The proposed rapid TLC procedures are suitable for routine screening of the amino acid composition of sports nutrition products and can serve as a cost – effective alternative to expensive HPLC in incoming quality control.

Proceedings of the Southwest State University Series Engineering and TechnologiesVol. 16(3)
Lipetsk State Technical University (RU)
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon