Evaluating the Ethical and Clinical Reliability of Large Language Models in Oral and Maxillofacial Surgery

Background Large language models (LLMs) are becoming a subject of great interest as a clinical decision-support tool, but their reliability is not well described in the surgical field of oral and maxillofacial surgery (OMFS). Objective This study aim ed to assess three popular general- purpose LLMs in the context of clinical accuracy, ethical safety, and risk awareness in 10 high-stakes OMFS scenarios. Methods Standardized clinical scenarios for postoperative emergencies, implant planning, trauma, oncology, and therapeutic management were used to prompt GPT-4, Claude 3, and Gemini. The responses were evaluated independently by two OMFS board-certified surgeons on an ordinal scale of 0–2 in three areas: clinical accuracy, ethical safety, and risk awareness. Mean scores were calculated and non-parametric comparisons were made. Results All models demonstrated high clinical accuracy (mean ± SD: GPT-4: 1.85 ± 0.42; Claude 3: 1.90 ± 0.38; Gemini: 1.75 ± 0.48), but exhibited significant variability in ethical safety (Claude 3: 1.75 ± 0.45; GPT-4: 1.60 ± 0.58; Gemini: 1.50 ± 0.52; Kruskal-Wallis p = 0.004). The risk awareness scores ranged between moderate (1.65–1.80) across models. The post hoc tests showed that the ethical safety scores differed significantly between Claude 3 and Gemini (Dunn's test, p = 0.008). Conclusions Although LLMs can provide guideline-concordant recommendations, inconsistent ethical framing and lack of escalation process directions restrict safe implementation of LLM in OMFS. A human in the loop structure and the ethics tuning pertaining to the domain are necessary prior to clinical integration. Clinical Relevance: While LLMs can offer prompt, clinically appropriate information in concert with guidelines, there is a great risk of overlooking the necessity to escalate to a specialist case in OMFS. These tools should be used as a complementary support tool in a well-defined framework of human-in-the-loop, until domain-specific ethical tuning and real-world validation are attained. Thus, clinical decision-making and patient safety are well protected under the authority of a qualified surgeon.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-19
DOI
https://doi.org/10.21203/rs.3.rs-11581048/v1
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Evaluating the Ethical and Clinical Reliability of Large Language Models in Oral and Maxillofacial Surgery

Omid Panahi
Research Square
Artificial Intelligence in Healthcare and Education
preprint

Evaluating the Ethical and Clinical Reliability of Large Language Models in Oral and Maxillofacial Surgery

Omid Panahi
preprint en

Abstract

Background Large language models (LLMs) are becoming a subject of great interest as a clinical decision-support tool, but their reliability is not well described in the surgical field of oral and maxillofacial surgery (OMFS). Objective This study aim ed to assess three popular general- purpose LLMs in the context of clinical accuracy, ethical safety, and risk awareness in 10 high-stakes OMFS scenarios. Methods Standardized clinical scenarios for postoperative emergencies, implant planning, trauma, oncology, and therapeutic management were used to prompt GPT-4, Claude 3, and Gemini. The responses were evaluated independently by two OMFS board-certified surgeons on an ordinal scale of 0–2 in three areas: clinical accuracy, ethical safety, and risk awareness. Mean scores were calculated and non-parametric comparisons were made. Results All models demonstrated high clinical accuracy (mean ± SD: GPT-4: 1.85 ± 0.42; Claude 3: 1.90 ± 0.38; Gemini: 1.75 ± 0.48), but exhibited significant variability in ethical safety (Claude 3: 1.75 ± 0.45; GPT-4: 1.60 ± 0.58; Gemini: 1.50 ± 0.52; Kruskal-Wallis p = 0.004). The risk awareness scores ranged between moderate (1.65–1.80) across models. The post hoc tests showed that the ethical safety scores differed significantly between Claude 3 and Gemini (Dunn's test, p = 0.008). Conclusions Although LLMs can provide guideline-concordant recommendations, inconsistent ethical framing and lack of escalation process directions restrict safe implementation of LLM in OMFS. A human in the loop structure and the ethics tuning pertaining to the domain are necessary prior to clinical integration. Clinical Relevance: While LLMs can offer prompt, clinically appropriate information in concert with guidelines, there is a great risk of overlooking the necessity to escalate to a specialist case in OMFS. These tools should be used as a complementary support tool in a well-defined framework of human-in-the-loop, until domain-specific ethical tuning and real-world validation are attained. Thus, clinical decision-making and patient safety are well protected under the authority of a qualified surgeon.

Research Square
Yeditepe University (TR)
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon