Relationship Between Chromatic Sensitivity and Retinal Structure in Early Glaucoma

Purpose: To investigate the correlations between retinal structure parameters and chromatic sensitivity in controls and people with various stages of primary open-angle glaucoma (POAG) and ocular hypertension (OHT). A secondary aim was to assess the diagnostic and predictive accuracy of red/green (RG) and yellow/blue (YB) chromatic thresholds in identifying early glaucomatous alterations. Methods: One hundred sixty-nine participants were recruited (n = 25 OHT, n = 33 early, n = 11 moderate, n = 11 severe POAG, and n = 89 controls) from the glaucoma clinic at St. Thomas's Hospital. Chromatic sensitivity was measured with the Color Assessment and Diagnostics (CAD) test. Macular retinal layers and peripapillary retinal nerve fiber layer thicknesses (pRNFLT) were measured using OCT. Results: Median pRNFLT was significantly reduced in people with glaucoma of all stages compared to age-matched controls and OHT (P < 0.001). Significant negative correlations were found between RG thresholds and whole retinal thickness, ganglion cell layer (GCL), inner plexiform layer, inner and outer retinal layers and retinal pigment epithelium thickness in controls and glaucoma subgroups, whereas YB thresholds were correlated with GCL, outer retinal layer thickness and pRNFLT. Early POAG patients showed increased color thresholds (median RG = 3.40, YB = 4.04 CAD units) when compared to controls (RG = 1.86, YB = 2.20 CAD units) (P < 0.001). RG and YB thresholds showed considerable accuracy in detecting early POAG (area under the curves = 0.81 and 0.86, respectively). Conclusions: Glaucoma patients show reduced chromatic sensitivity in every stage of severity. Results suggest that changes in both outer and inner retinal layers influence chromatic sensitivity. The outer retinal layer thickness is more strongly associated with color thresholds across all disease severity stages in glaucoma.

Authors

Institutions

Publication Details

Journal
Investigative Ophthalmology & Visual Science
Published
2026-11-19
DOI
https://doi.org/10.1167/iovs.67.13.34
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Relationship Between Chromatic Sensitivity and Retinal Structure in Early Glaucoma

Irene Ctori, Giovanni Montesano, Alison M. Binns, Sui Hsien Wong et al.
Investigative Ophthalmology & Visual Science
Glaucoma and retinal disorders
article

Relationship Between Chromatic Sensitivity and Retinal Structure in Early Glaucoma

Irene Ctori, Giovanni Montesano, Alison M. Binns, Sui Hsien Wong, Kin Sheng Lim, John L. Barbur, Aiman Hafeez
article en

Abstract

Purpose: To investigate the correlations between retinal structure parameters and chromatic sensitivity in controls and people with various stages of primary open-angle glaucoma (POAG) and ocular hypertension (OHT). A secondary aim was to assess the diagnostic and predictive accuracy of red/green (RG) and yellow/blue (YB) chromatic thresholds in identifying early glaucomatous alterations. Methods: One hundred sixty-nine participants were recruited (n = 25 OHT, n = 33 early, n = 11 moderate, n = 11 severe POAG, and n = 89 controls) from the glaucoma clinic at St. Thomas's Hospital. Chromatic sensitivity was measured with the Color Assessment and Diagnostics (CAD) test. Macular retinal layers and peripapillary retinal nerve fiber layer thicknesses (pRNFLT) were measured using OCT. Results: Median pRNFLT was significantly reduced in people with glaucoma of all stages compared to age-matched controls and OHT (P < 0.001). Significant negative correlations were found between RG thresholds and whole retinal thickness, ganglion cell layer (GCL), inner plexiform layer, inner and outer retinal layers and retinal pigment epithelium thickness in controls and glaucoma subgroups, whereas YB thresholds were correlated with GCL, outer retinal layer thickness and pRNFLT. Early POAG patients showed increased color thresholds (median RG = 3.40, YB = 4.04 CAD units) when compared to controls (RG = 1.86, YB = 2.20 CAD units) (P < 0.001). RG and YB thresholds showed considerable accuracy in detecting early POAG (area under the curves = 0.81 and 0.86, respectively). Conclusions: Glaucoma patients show reduced chromatic sensitivity in every stage of severity. Results suggest that changes in both outer and inner retinal layers influence chromatic sensitivity. The outer retinal layer thickness is more strongly associated with color thresholds across all disease severity stages in glaucoma.

Investigative Ophthalmology & Visual ScienceVol. 67(13)
Moorfields Eye Hospital NHS Foundation Trust (GB), University of Hertfordshire (GB), St George's, University of London (GB), King's College London (GB), Guy's and St Thomas' NHS Foundation Trust (GB), NIHR Moorfields Biomedical Research Centre (GB), King's College School (GB), City St George's, University of London (GB), University College London (GB)
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon