Parametric fluid mechanics study of vessel geometry and blood rheology: Structural absence of a Pareto trade-off

Cardiovascular hemodynamics in narrowed arteries are heavily dictated by local geometry and complex fluid properties, but multi-objective optimization loops using full Navier–Stokes solves remain computationally prohibitive. The aim of this study was to evaluate a multi-objective parametric framework for non-Newtonian blood flow through stenosed arteries and determine whether competing trade-offs exist between geometric narrowing and fluid rheology. The framework combines a Gaussian-parametrized stenosis model with the Carreau–Yasuda rheological law under a reduced-order, lubrication-theory formulation. At each axial position, the model prescribes a parabolic velocity profile scaled by mass conservation, a kinematic approximation that replaces a coupled Navier–Stokes solve. Two separate parametric optimization analyses were conducted with an NSGA-II scheme over three engineering metrics (peak wall shear stress, pressure drop, and viscous energy loss). The first analysis varied stenosis severity and width with rheology fixed, whereas the second varied rheological parameter (μ₀, , ) with a severe stenosis fixed. Across four representative configurations, peak velocity and maximum wall shear stress depended on severity alone (0.57 m/s and 1.26 Pa at δ=0.3; 1.00 m/s and 3.80 Pa at δ=0.6), whereas pressure drop and energy loss also rose with stenosis width. Both algorithmic runs converged to a single corner of their mathematical domains rather than a spread Pareto front. Analytical arguments and uniform sampling grids confirmed that each objective changes monotonically with each isolated parameter, causing a single corner solution to dominate each domain. The framework demonstrates the structural behavior of the simplified fluid formulation rather than competing physical optima. An independent, transient 3D COMSOL simulation illustrated a proximal–distal pressure difference varying over the cardiac cycle (peak 3.5 mmHg) to highlight transient physical behaviors omitted by steady-state models. These findings suggest that reduced-order computational formulations structurally govern local fluid indices, demonstrating that geometry and rheology do not present a Pareto trade-off within this kinematic framework.

Authors

Publication Details

Journal
Narra X
Published
2026-11-18
DOI
https://doi.org/10.52225/narrax.v4i3.353
Primary Topic
Blood properties and coagulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Parametric fluid mechanics study of vessel geometry and blood rheology: Structural absence of a Pareto trade-off

Nuraini Binti Abdul Aziz, Jonathan Liviera Marpaung, Tulus Joseph Herianto Marpaung, Tulus Tulus et al.
Narra X
Blood properties and coagulation
article

Parametric fluid mechanics study of vessel geometry and blood rheology: Structural absence of a Pareto trade-off

Nuraini Binti Abdul Aziz, Jonathan Liviera Marpaung, Tulus Joseph Herianto Marpaung, Tulus Tulus, Suriati Suriati, Putri K. Nasution, Muhammad R. Syahputra
article en

Abstract

Cardiovascular hemodynamics in narrowed arteries are heavily dictated by local geometry and complex fluid properties, but multi-objective optimization loops using full Navier–Stokes solves remain computationally prohibitive. The aim of this study was to evaluate a multi-objective parametric framework for non-Newtonian blood flow through stenosed arteries and determine whether competing trade-offs exist between geometric narrowing and fluid rheology. The framework combines a Gaussian-parametrized stenosis model with the Carreau–Yasuda rheological law under a reduced-order, lubrication-theory formulation. At each axial position, the model prescribes a parabolic velocity profile scaled by mass conservation, a kinematic approximation that replaces a coupled Navier–Stokes solve. Two separate parametric optimization analyses were conducted with an NSGA-II scheme over three engineering metrics (peak wall shear stress, pressure drop, and viscous energy loss). The first analysis varied stenosis severity and width with rheology fixed, whereas the second varied rheological parameter (μ₀, , ) with a severe stenosis fixed. Across four representative configurations, peak velocity and maximum wall shear stress depended on severity alone (0.57 m/s and 1.26 Pa at δ=0.3; 1.00 m/s and 3.80 Pa at δ=0.6), whereas pressure drop and energy loss also rose with stenosis width. Both algorithmic runs converged to a single corner of their mathematical domains rather than a spread Pareto front. Analytical arguments and uniform sampling grids confirmed that each objective changes monotonically with each isolated parameter, causing a single corner solution to dominate each domain. The framework demonstrates the structural behavior of the simplified fluid formulation rather than competing physical optima. An independent, transient 3D COMSOL simulation illustrated a proximal–distal pressure difference varying over the cardiac cycle (peak 3.5 mmHg) to highlight transient physical behaviors omitted by steady-state models. These findings suggest that reduced-order computational formulations structurally govern local fluid indices, demonstrating that geometry and rheology do not present a Pareto trade-off within this kinematic framework.

Narra XVol. 4(3)
Blood properties and coagulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon