Multi-frequency phase-difference microwave sensing for moisture detection in fiberglass insulated pipelines

Moisture ingress in insulated pipelines can promote corrosion under insulation and increase operational and safety risks, while early detection remains challenging because the affected region is concealed beneath the insulation. This study presents a non-invasive multi-frequency phase-difference microwave sensing framework for assessing localized moisture conditions in fiberglass-insulated steel pipelines. The system operates over the 2.40–2.42 GHz band using an IEEE 802.11 OFDM structure with 64 subcarriers and a dual-receiver configuration. Differential phase responses are extracted across the subcarriers, combined using circular-mean aggregation to account for phase periodicity and exploit frequency diversity, and subsequently processed using exponential moving average (EMA) filtering. Full-wave electromagnetic simulations were used to evaluate the sensing principle under controlled variations in standoff distance, insulation thickness, pipe radius, and moisture condition. Ablation analysis demonstrated a progressive reduction in response ambiguity from 16 ambiguous points for the amplitude-based benchmark, to 11 for single-frequency phase difference, 9 following multi-frequency circular averaging, and only 3 using the complete circular-mean-plus-EMA method, corresponding to approximate discrimination performances of 84%, 89%, 91%, and 97%, respectively. The simulations further showed preserved separation among the dry and moisture conditions for insulation thicknesses of 1–5 cm and pipe radii of 0.5–4 cm. Experimental proof-of-concept measurements were conducted using a dry reference and localized water volumes of 1, 40, and 120 ml, corresponding to nominal volumetric moisture fractions of approximately 0.031%, 1.228%, and 3.684%, respectively. Measurements were performed at 5, 15, and 30 cm standoff distances with ten repeated acquisitions per prepared condition. At 5 and 15 cm, the dry, low-, medium-, and severe-moisture conditions exhibited non-overlapping 95% confidence intervals, indicating clear separation of their estimated mean responses. At 30 cm, the 1 ml and 40 ml responses substantially overlapped, while the severe-moisture condition remained more distinguishable, demonstrating reduced discrimination between lower moisture levels at increased standoff distance. Overall, the results demonstrate the proof-of-concept feasibility of multi-frequency differential-phase sensing for reducing response ambiguity and distinguishing localized moisture conditions under the investigated configuration, while identifying standoff distance as an important practical factor governing discrimination performance.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-19
DOI
https://doi.org/10.1038/s41598-026-80506-0
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multi-frequency phase-difference microwave sensing for moisture detection in fiberglass insulated pipelines

Muhammad Firdaus Akbar, Saleh Abu Dabous, Mohamed Ait Gacem
Scientific Reports
Microwave and Dielectric Measurement Techniques
article

Multi-frequency phase-difference microwave sensing for moisture detection in fiberglass insulated pipelines

Muhammad Firdaus Akbar, Saleh Abu Dabous, Mohamed Ait Gacem
article en

Abstract

Moisture ingress in insulated pipelines can promote corrosion under insulation and increase operational and safety risks, while early detection remains challenging because the affected region is concealed beneath the insulation. This study presents a non-invasive multi-frequency phase-difference microwave sensing framework for assessing localized moisture conditions in fiberglass-insulated steel pipelines. The system operates over the 2.40–2.42 GHz band using an IEEE 802.11 OFDM structure with 64 subcarriers and a dual-receiver configuration. Differential phase responses are extracted across the subcarriers, combined using circular-mean aggregation to account for phase periodicity and exploit frequency diversity, and subsequently processed using exponential moving average (EMA) filtering. Full-wave electromagnetic simulations were used to evaluate the sensing principle under controlled variations in standoff distance, insulation thickness, pipe radius, and moisture condition. Ablation analysis demonstrated a progressive reduction in response ambiguity from 16 ambiguous points for the amplitude-based benchmark, to 11 for single-frequency phase difference, 9 following multi-frequency circular averaging, and only 3 using the complete circular-mean-plus-EMA method, corresponding to approximate discrimination performances of 84%, 89%, 91%, and 97%, respectively. The simulations further showed preserved separation among the dry and moisture conditions for insulation thicknesses of 1–5 cm and pipe radii of 0.5–4 cm. Experimental proof-of-concept measurements were conducted using a dry reference and localized water volumes of 1, 40, and 120 ml, corresponding to nominal volumetric moisture fractions of approximately 0.031%, 1.228%, and 3.684%, respectively. Measurements were performed at 5, 15, and 30 cm standoff distances with ten repeated acquisitions per prepared condition. At 5 and 15 cm, the dry, low-, medium-, and severe-moisture conditions exhibited non-overlapping 95% confidence intervals, indicating clear separation of their estimated mean responses. At 30 cm, the 1 ml and 40 ml responses substantially overlapped, while the severe-moisture condition remained more distinguishable, demonstrating reduced discrimination between lower moisture levels at increased standoff distance. Overall, the results demonstrate the proof-of-concept feasibility of multi-frequency differential-phase sensing for reducing response ambiguity and distinguishing localized moisture conditions under the investigated configuration, while identifying standoff distance as an important practical factor governing discrimination performance.

Scientific Reports
Universiti Sains Malaysia (MY), University of Sharjah (AE)
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.