Feasibility of i-Gel Airway Management During Awake Craniotomy Using the Asleep–Awake–Asleep Method: A Retrospective Study

Background and Objectives: The i-gel is a second-generation supraglottic airway device that may be suitable for repeated airway management during awake craniotomy (AC) using the asleep–awake–asleep (AAA) technique. This study evaluated the feasibility of using the i-gel for airway management during AC. Materials and Methods: This single-center retrospective study included 366 patients in whom AC for brain tumor resection using the AAA technique was planned. The primary outcome was the overall success rate of i-gel-only airway management. Secondary outcomes included success rates during each asleep phase, rescue airway strategies, airway-related adverse events, and factors associated with second-phase failure. Results: Initial-phase i-gel management was successful in 363/366 patients (99.2%). Among these 363 patients, second-phase i-gel management was successful in 345 (95.0%). Overall, both asleep phases were completed using the i-gel alone in 345/366 patients (94.3%). Of the 18 second-phase failures, 10 involved inadequate ventilation despite successful insertion, and eight involved difficult or failed reinsertion. Rescue airway management was successful in all 18 patients, including seven patients who underwent fiberoptic-guided tracheal intubation through the i-gel. No severe hypoxemia or clinically significant airway injury occurred. Initial suboptimal i-gel fit was associated with second-phase failure (adjusted odds ratio, 7.05; 95% confidence interval, 2.58–18.97; p < 0.001). Conclusions: The i-gel provided successful airway management in most patients undergoing AC with the AAA technique. An initially suboptimal fit may serve as a warning signal for second-phase failure, and appropriate rescue airway strategies should be readily available.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2026-11-19
DOI
https://doi.org/10.3390/medicina62112279
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Feasibility of i-Gel Airway Management During Awake Craniotomy Using the Asleep–Awake–Asleep Method: A Retrospective Study

Shigeru Inoue, Takehito Sato, Koichi Akiyama, Yui Somura
Medicina
Airway Management and Intubation Techniques
article

Feasibility of i-Gel Airway Management During Awake Craniotomy Using the Asleep–Awake–Asleep Method: A Retrospective Study

Shigeru Inoue, Takehito Sato, Koichi Akiyama, Yui Somura
article en

Abstract

Background and Objectives: The i-gel is a second-generation supraglottic airway device that may be suitable for repeated airway management during awake craniotomy (AC) using the asleep–awake–asleep (AAA) technique. This study evaluated the feasibility of using the i-gel for airway management during AC. Materials and Methods: This single-center retrospective study included 366 patients in whom AC for brain tumor resection using the AAA technique was planned. The primary outcome was the overall success rate of i-gel-only airway management. Secondary outcomes included success rates during each asleep phase, rescue airway strategies, airway-related adverse events, and factors associated with second-phase failure. Results: Initial-phase i-gel management was successful in 363/366 patients (99.2%). Among these 363 patients, second-phase i-gel management was successful in 345 (95.0%). Overall, both asleep phases were completed using the i-gel alone in 345/366 patients (94.3%). Of the 18 second-phase failures, 10 involved inadequate ventilation despite successful insertion, and eight involved difficult or failed reinsertion. Rescue airway management was successful in all 18 patients, including seven patients who underwent fiberoptic-guided tracheal intubation through the i-gel. No severe hypoxemia or clinically significant airway injury occurred. Initial suboptimal i-gel fit was associated with second-phase failure (adjusted odds ratio, 7.05; 95% confidence interval, 2.58–18.97; p < 0.001). Conclusions: The i-gel provided successful airway management in most patients undergoing AC with the AAA technique. An initially suboptimal fit may serve as a warning signal for second-phase failure, and appropriate rescue airway strategies should be readily available.

MedicinaVol. 62(11)
Nagoya University Hospital (JP), Nagoya University (JP)
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon