Probabilistic cradle‐to‐gate carbon footprint of e‐methanol under coupled electricity and CO 2 ‐source conditions: Comparison with published projects and an industrial‐park application

Electricity supply, CO 2 sourcing and process heat determine whether e‐methanol has a lower cradle‐to‐gate carbon footprint than fossil methanol. We developed a screening model for 1 kg methanol and propagated uncertainty in four foreground parameters using Monte Carlo analysis. Against a natural‐gas‐methanol reference of 0.944 kg CO 2 e per kg of methanol, median break‐even electricity factors were 0.075 and 0.053 kg CO 2 e/kWh for high‐concentration and point‐source CO 2 , with fifth‐percentile (P5) thresholds of 0.069 and 0.048. Sampling residual heat over 0–4 MJ per kg of methanol lowered the point‐source P5 threshold to 0.033. For the high‐temperature direct‐air‐capture route, adding an illustrative U.S.‐average upstream natural‐gas burden lowered the break‐even factor from 0.027 to 0.018 kg CO 2 e/kWh. In the 100,000 t/y park case, the 97% wind‐equivalent, 100‐km point‐source configuration had a footprint of 0.921 kg CO 2 e per kg of methanol; lower capture‐heat efficiency reversed its small advantage over the reference. These results identify electricity intensity, CO 2 supply and heat integration as key variables for early‐stage screening.

Authors

Institutions

Publication Details

Journal
Environmental Progress & Sustainable Energy
Published
2026-11-18
DOI
https://doi.org/10.1002/ep.70806
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Probabilistic cradle‐to‐gate carbon footprint of e‐methanol under coupled electricity and CO 2 ‐source conditions: Comparison with published projects and an industrial‐park application

Hao Zhou, Jingjing Zhan, Yuqing Liu, Jieyi Li
Environmental Progress & Sustainable Energy
Hybrid Renewable Energy Systems
article

Probabilistic cradle‐to‐gate carbon footprint of e‐methanol under coupled electricity and CO 2 ‐source conditions: Comparison with published projects and an industrial‐park application

Hao Zhou, Jingjing Zhan, Yuqing Liu, Jieyi Li
article en

Abstract

Electricity supply, CO 2 sourcing and process heat determine whether e‐methanol has a lower cradle‐to‐gate carbon footprint than fossil methanol. We developed a screening model for 1 kg methanol and propagated uncertainty in four foreground parameters using Monte Carlo analysis. Against a natural‐gas‐methanol reference of 0.944 kg CO 2 e per kg of methanol, median break‐even electricity factors were 0.075 and 0.053 kg CO 2 e/kWh for high‐concentration and point‐source CO 2 , with fifth‐percentile (P5) thresholds of 0.069 and 0.048. Sampling residual heat over 0–4 MJ per kg of methanol lowered the point‐source P5 threshold to 0.033. For the high‐temperature direct‐air‐capture route, adding an illustrative U.S.‐average upstream natural‐gas burden lowered the break‐even factor from 0.027 to 0.018 kg CO 2 e/kWh. In the 100,000 t/y park case, the 97% wind‐equivalent, 100‐km point‐source configuration had a footprint of 0.921 kg CO 2 e per kg of methanol; lower capture‐heat efficiency reversed its small advantage over the reference. These results identify electricity intensity, CO 2 supply and heat integration as key variables for early‐stage screening.

Environmental Progress & Sustainable Energy
Dalian University of Technology (CN)
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon