Floating thrombus in an ascending aortic graft presenting with acute upper limb ischemia after ascending aorta–femoral bypass: a case report

Background A floating thrombus within an ascending aortic graft is extremely rare, with only a few reported cases originating from the proximal anastomosis of an ascending aorta–femoral (Ao–Fem) bypass performed alongside central repair for acute type A aortic dissection. Case presentation A 52-year-old man with acute Stanford type A aortic dissection complicated by lower-extremity malperfusion underwent ascending aortic replacement and Ao–Fem bypass. One year and 9 months of this procedure, he suddenly developed pain and numbness in his right upper limb. Contrast-enhanced computed tomography (CT) revealed acute arterial occlusion of the right upper extremity, and emergency thrombectomy was performed. Postoperative CT revealed a floating thrombus protruding from the proximal portion of the Ao–Fem bypass into the ascending aortic graft. Given the high risk of recurrent embolization, semi-emergent open surgical thrombectomy was performed. An organized thrombus approximately 10 cm in length was identified within the graft and completely removed. Coagulation screening revealed hyperhomocysteinemia. The patient’s postoperative course was uneventful, and no recurrence was observed with continued anticoagulation therapy. Conclusion Herein, we report an extremely rare case of a floating thrombus protruding into the ascending aortic graft from the proximal anastomotic site of an Ao–Fem bypass in the late postoperative phase, which resulted in acute upper limb ischemia. Structural factors and metabolic predispositions were considered as contributory factors. In late postoperative embolic events, intragraft thrombosis or thrombus formation arising from an occluded graft should be considered, warranting prompt imaging and surgical management, along with strategies aimed at recurrence prevention.

Authors

Institutions

Publication Details

Journal
Journal of Cardiothoracic Surgery
Published
2026-11-19
DOI
https://doi.org/10.1186/s13019-026-04826-y
Primary Topic
Aortic Thrombus and Embolism
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Floating thrombus in an ascending aortic graft presenting with acute upper limb ischemia after ascending aorta–femoral bypass: a case report

Soichiro Ota, Masashi Tanaka, Fumihiro Kitashima, Kosuke Ajisaka et al.
Journal of Cardiothoracic Surgery
Aortic Thrombus and Embolism
article

Floating thrombus in an ascending aortic graft presenting with acute upper limb ischemia after ascending aorta–femoral bypass: a case report

Soichiro Ota, Masashi Tanaka, Fumihiro Kitashima, Kosuke Ajisaka, Yuki Hayashi, Naoki Eguchi, Keita Kamata, Hirohisa Minamisawa, Atsushi Harada
article en

Abstract

Background A floating thrombus within an ascending aortic graft is extremely rare, with only a few reported cases originating from the proximal anastomosis of an ascending aorta–femoral (Ao–Fem) bypass performed alongside central repair for acute type A aortic dissection. Case presentation A 52-year-old man with acute Stanford type A aortic dissection complicated by lower-extremity malperfusion underwent ascending aortic replacement and Ao–Fem bypass. One year and 9 months of this procedure, he suddenly developed pain and numbness in his right upper limb. Contrast-enhanced computed tomography (CT) revealed acute arterial occlusion of the right upper extremity, and emergency thrombectomy was performed. Postoperative CT revealed a floating thrombus protruding from the proximal portion of the Ao–Fem bypass into the ascending aortic graft. Given the high risk of recurrent embolization, semi-emergent open surgical thrombectomy was performed. An organized thrombus approximately 10 cm in length was identified within the graft and completely removed. Coagulation screening revealed hyperhomocysteinemia. The patient’s postoperative course was uneventful, and no recurrence was observed with continued anticoagulation therapy. Conclusion Herein, we report an extremely rare case of a floating thrombus protruding into the ascending aortic graft from the proximal anastomotic site of an Ao–Fem bypass in the late postoperative phase, which resulted in acute upper limb ischemia. Structural factors and metabolic predispositions were considered as contributory factors. In late postoperative embolic events, intragraft thrombosis or thrombus formation arising from an occluded graft should be considered, warranting prompt imaging and surgical management, along with strategies aimed at recurrence prevention.

Journal of Cardiothoracic Surgery
Nihon University (JP)
Aortic Thrombus and Embolism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon