Acute reduction in inferior vena cava diameter following alcohol consumption: a substudy of a pilot cluster-randomized trial
Background Acute alcohol consumption induces cardiovascular and diuretic effects; however, its influence on intravascular volume distribution remains poorly understood. Inferior vena cava (IVC) ultrasonography is a non-invasive method for assessing intravascular volume status, but changes in IVC morphology following alcohol consumption have not previously been investigated. This study evaluated acute changes in IVC measurements and vital signs after alcohol consumption. Methods This prespecified physiological substudy analyzed 59 healthy adult social drinkers enrolled in a pilot cluster-randomized trial. Maximum IVC diameter and respiratory collapsibility were assessed immediately before and after a standardized 2-hour ad libitum drinking session. Heart rate, blood pressure, breath alcohol concentration, and alcohol intake were serially measured throughout the session. Exploratory univariable linear regression analyses were performed to identify factors associated with post-drinking IVC diameter and changes in IVC diameter. Results Maximum IVC diameter significantly decreased after alcohol consumption, from 14.4 ± 3.4 mm to 10.8 ± 3.0 mm (paired t test, P < 0.001). The proportion of participants with respiratory collapsibility ≥ 50% increased from 79.3% to 91.4%, although this difference was not statistically significant (McNemar's test, P = 0.096). During alcohol consumption, heart rate and shock index gradually increased, whereas systolic and diastolic blood pressure decreased. In exploratory analyses, pre-drinking maximum IVC diameter was the strongest predictor of post-drinking IVC measurements and was inversely associated with the change in IVC diameter from baseline (β = −0.653; 95% CI, − 0.862 to − 0.444; P < 0.001). Conclusions Acute alcohol consumption was associated with a significant reduction in maximum IVC diameter, suggesting alterations in intravascular volume distribution beyond previously recognized cardiovascular responses. The magnitude of this reduction was strongly associated with pre-drinking IVC diameter, highlighting the potential importance of baseline intravascular volume status in determining the physiological response to alcohol.
Authors
- Takahiro Hadano (ORCID: https://orcid.org/0009-0007-8765-5972)
- Masamori Iwase
- Yuta Komano
- Kentaro Umeda (ORCID: https://orcid.org/0000-0001-7761-4703)
- Yuto Iioka
- Hisashi Yoshimoto (ORCID: https://orcid.org/0000-0001-9168-9218)
- Masahiko Gosho (ORCID: https://orcid.org/0000-0002-5973-9163)
- Takafumi Fukuda (ORCID: https://orcid.org/0000-0002-3185-7192)
- Kensuke Shimada (ORCID: https://orcid.org/0000-0002-2106-0753)
- Takahisa INABA
- Tetsuya Kodaira
- Takayo Kawabata
- Yuko Kusano
- Kentaro Minami
Institutions
- University of Tsukuba (JP)
- Kirin (Japan) (JP)
- University of Tsukuba Hospital (JP)
- Kirin Holdings Company, Limited (Japan) (JP)
- Kirin Brewery Company, Limited (Japan) (JP)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-20
- DOI
- https://doi.org/10.21203/rs.3.rs-11609675/v1
- Primary Topic
- Alcohol Consumption and Health Effects
- Type
- preprint